LED
Definition
viewer
Options of Gate
1
opening direction
2
Automatic closing
There actions of
photocell/ safety
3
edge/ loop de-
tector when they
detecting
4
Motor speed
The deceleration
5
setting for gate
moving
Deceleration
6
speed
(% full speed)
Over current
7
setting
EN
34
Function
Value
1-1
Clockwise opening
Counterclckwise
1-2
opening
No automatic
2-0
closing
2-1
5 seconds
2-2
15 seconds
2-3
30 seconds
2-4
45 seconds
2-5
60 seconds
2-6
80 seconds
2-7
120 seconds
2-8
180 seconds
3-1
Please the function
3-2
setting after H & J
3-3
4-1
Slow
4-2
Middle
4-3
Fast
4-4
Very fast
5-1
75% of full distance
5-2
80%
5-3
85%
5-4
90%
5-5
95%
6-1
80%
6-2
60%
6-3
40%
6-4
25%
7-1
2A
7-2
3A
7-3
4A
7-4
5A
7-5
6A
7-6
7A
Description
The function can adjust the direction
of gate opening. The factory setting
is « 1-1 ».
This function allows to adjust the
gate closing automatic after the
paused time.
The factory setting is « 2-0 » : no
automatic closing
Please do the function setting after
H&J
The factory setting is « 3-1 »
The factory setting is « 4-3 »
The factory setting is « 5-1 »
The factory setting is « 6-3 »
The function can adjust the running
force of motor to be compatible with
the gate weight.
The factory setting is « 7-5 »