OPERATION OF THE HOB
4. Within 10 seconds, set the power level by touching the slide control.
The cooking zone starts at the level that has been set.
▷
▷
The extraction unit switches on automatically from position 3. The extraction unit can be
switched on manually at position 1 and 2.
The extractor unit automatically switches on with the necessary extraction speed. By
▷
default the automatic extraction mode is active.
Set a higher or lower level with the slide control.
▷
Touch the key 'Automatic extraction mode' to deactivate the automatic extraction mode.
▷
The extraction can now be set manually, if desired. See 'Operating the extractor unit'.
After 10 seconds the slide control will switch off and the cooking time counter is hidden.
▷
Boost
You can use the boost function to cook for max. 5 minutes at the highest cooking level. You can
use the Boost function for a maximum of two cooking zones alongside each other at the same
time.
1. Touch power level P to select the Boost function.
'P' shows on the display.
▷
▷
After the maximum boost time the power will be reduced to power level 9.
Pan detection symbol
When the pan detection symbol appears in the display:
•
you have not placed a pan on the correct cooking zone;
•
the pan you're using is not suitable for induction cooking;
•
the pan is too small or not properly centred on the cooking zone.
The cooking zone will not work unless there is a suitable pan on the cooking zone.
▷