AKTH15: Hold the air tank grips.
(See Fig.X)
39. TAKE CARE TO TRANSPORT THE COM-
PRESSOR CORRECTLY, DO NOT OVER-
TURN IT OR LIFT IT WITH HOOKS OR
ROPES.
40. DO NOT PUT FINGERS IN THE BLEEDER
OR CLEARANCES IN THE HOUSING.
This can result in injury, electric shock or
burns.
3. SPECIFICATIONS
Product No.
Dimensions
Weight
Power supply
Rated current
Tank capacity
Motor power
Protective earthing
Protective structure
Working temperature
Working humidity
Height above sea level
Storage temperature
Storage humidity
Pressure switch working
range
Fluid
Pollution degree
L
W
H
85%RH or less. No dew condensation.
85%RH or less. No dew condensation.
10
41. DO NOT USE ANY ADAPTER PLUGS
WITH THE COMPRESSOR
The compressor is factory-equipped with a
specific electric cord and plug for connection
to a proper electric power source. Never
modify the plug in any way. Do not use any
adapter plugs with the compressor.
42. IF OPERATING THIS COMPRESSOR IN A
DAMP LOCATION IS UNAVOIDABLE, USE
A GROUND FAULT CIRCUIT INTERRUPT-
ER (GFCI) PROTECTED SUPPLY
Use of a GFCI reduces the risk of electric
shock.
43. USE THE APPROPRIATE TOOL HOSE
BECAUSE THE FOLLOWING PRES-
SURES MAY BE EMITTED FROM THE AIR
CHUCK IN THE EVENT OF MACHINE
FAILURE.
High pressure air chuck: 34.5 bar
Regular pressure air chuck: 15.5 bar
AKHL1320E (CE)
573mm
351mm
336mm
17.6kg
a.c.230V±10%
50Hz±1% Ø1
6.5A
5.0L×2
2HP
Class Ι
IP20
0°C to +40°C
UP to 1000m
-10°C to +50°C
OFF: 34.5 bar
ON: 30 bar
air
2

Publicité

loading

Ce manuel est également adapté pour:

Powerlite akhl1320ce