INDEX
1.
BURNER DESCRIPTION . . . . . . . . . . .
1.1
Burner equipment . . . . . . . . . . . . . . . . .
2.
TECHNICAL DATA . . . . . . . . . . . . . . . .
2.1
Technical data . . . . . . . . . . . . . . . . . . . .
2.2
Overall dimensions . . . . . . . . . . . . . . . .
2.3
Working field . . . . . . . . . . . . . . . . . . . . .
3.
INSTALLATION . . . . . . . . . . . . . . . . . .
3.1
Boiler fixing . . . . . . . . . . . . . . . . . . . . . .
3.2
Probe-electrode positioning . . . . . . . . . .
3.3
Gas feeding line . . . . . . . . . . . . . . . . . .
3.4
Electrical wiring . . . . . . . . . . . . . . . . . . .
3.4.1 Electrical wiring with gas leak control 
device . . . . . . . . . . . . . . . . . . . . . . . . . .
4.
WORKING . . . . . . . . . . . . . . . . . . . . . . .
4.1 Combustion adjustment . . . . . . . . . . . . .
1.
BURNER DESCRIPTION
Gas burner with one stage working.
CE marking according to Gas Appliance Directive 90/396/EEC; PIN 0063AP6680.
According to Directives: Electromagnetic Compatibility 89/336/EEC - 2004/108/EC, Low Voltage 73/23/EEC -
2006/95/EC and Machine 2006/42/EC.
The burner is approved for intermittent operation as per Directive EN 676.
The burner meets protection level of IP X0D (IP 40), EN 60529.
Gas train according to EN 676.
1 – Air damper
2 – Screws for fixing the air-damper
3 – 7 pole socket for electrical supply
and control
4 – 6 pole socket for gas train
5 – Cable grommet
6 – Screw for fixing the cover
7 – Air pressure switch
8 – Control box
9 – Reset button with lock-out lamp
NOTES:
– The cable grommet (5) supplied with the burner, must be fitted to the same side of the gas train.
– After having installed the burner verify the access to the fixing screws of the cover.
If necessary replace them with the fixing screws (6, Fig. 1) supplied as equipment.
1.1 BURNER EQUIPMENT
Insulating gasket . . . . . . . . . . . No. 1
Cable grommet . . . . . . . . . . . . No. 1
Hinge . . . . . . . . . . . . . . . . . . . . No. 1
20033828
1
4.2 Combustion head setting. . . . . . . . . . . . .
1
4.3 Air damper setting . . . . . . . . . . . . . . . . . .
4.4 Combustion check. . . . . . . . . . . . . . . . . .
2
4.5 Air pressure switch . . . . . . . . . . . . . . . . .
2
4.6 Burner start-up cycle . . . . . . . . . . . . . . . .
2
4.7 Start-up cycle diagnostics . . . . . . . . . . . .
2
4.8 Resetting the control box and using 
diagnostics . . . . . . . . . . . . . . . . . . . . . . .
3
3
WARNINGS 
5.
to avoid burnout or bad combustion 
4
of the burner . . . . . . . . . . . . . . . . . . . . . . 10
4
5
6.
MAINTENANCE . . . . . . . . . . . . . . . . . . . 10
7.
FAULTS / SOLUTIONS . . . . . . . . . . . . . . 12
5
6
8.
STANDARD ELECTRICAL WIRING . . . 14
6
9
8
7
6
4
5
Screws and nuts for flange to be fixed to boiler . . . . No. 4
Screws for fixing the cover . . . . . . . . . . . . . . . . . . . No. 3
7 pin plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
1
GB
Fig. 1
D11054
3
6
7
7
7
8
8
9
1
2
2

Publicité

loading

Ce manuel est également adapté pour: