LERBAKKEN 10, 8410 ROENDE DENMARK
Module 9116B1
Terminal 51-52, 51-53
Ui, Vmax
30 V
Ii, Imax
120 mA
Pi
900 mW
Ci
3 nF
Li
1 μH
Module 9116B1
Group
Terminal 51-54, 52-54
Uo, Voc
28 V
IIC or A,B
Io, Isc
93 mA
IIB or C,E,F
Po
650 mW
IIA or D,G
Module 9116B1
Group
Terminal 51-53
Uo, Voc
28 V
IIC or A,B
Io, Isc
1.1 mA
IIB or C,E,F
Po
8 mW
IIA or D,G
Module 9116B1
Group
Terminal 51-52
Uo, Voc
8.3 V
IIC or A,B
Io, Isc
0.2 mA
IIB or C,E,F
Po
0.4 mW
IIA or D,G
Module 9116B1
Group
Terminal 41,42,43,44
Uo, Voc
8.3 V
IIC or A,B
Io, Isc
13.1 mA
IIB or C,E,F
Po
27.3 mW
IIA or D,G
Installation notes:
In Class I, Division 2 installations, the subject equipment shall be mounted within a too-secured enclosure
which is capable of accepting one or more of the Class I, Division 2 wiring methods specified in the the
National Electrical Code (ANSI/NFPA 70) or Canadian Electrical Code (C22.1).
In Zone 2 installations, the subject equipment shall be mounted within a tool secured enclosure which is
capable of accepting one or more of the Zone 2 wiring methods specified in the National Electrical Code
(ANSI/NFPA 70) or the Canadian Electrical Code (C22.1). Where installed in outdoor or potentially wet
locations, the enclosure shall, at a minimum, meet the requirements of IP54.
In Zone 2 installations, the installer shall ensure protection of supply terminals against transient voltages
exceeding 140% of the rated supply voltage.
Install in environments rated Pollution Degree 2 or better; overvoltage category I or II.
The module must be supplied from a Power Supply having double or reinforced insulation.
The use of stranded wires is not permitted for mains wiring except when wires are fitted with cable ends.
For installation on the 9400 Power Rail the power must be supplied from Power Control Module Unit 9410.
The module is galvanic isolated and does not require grounding.
Use 60 / 75 ºC Copper Conductors with wire Size AWG: (26-14).
Warning: Substitution of components may impair intrinsic safety.
Warning: To prevent ignition of the explosive atmospheres, disconnect power before servicing and do not
separate connectors when energized and an explosive gas mixture is present.
Warning: Do not mount or remove modules from the Power Rail when an explosive gas mixture is present.
Revision date:
2019-04-04
Co
Lo
Lo/Ro
80 nF
4 mH
54 μH/Ω
640 nF
16 mH 218 μH/Ω
2.1 μF
32 mH 436 μH/Ω
Co
Lo
Lo/Ro
80 nF 1000 mH
4 mH/Ω
640 nF 1000 mH 17 mH/Ω
2.1 μF 1000 mH 35 mH/Ω
Co
Lo
Lo/Ro
7 μF 1000 mH 100 mH/Ω
73 μF 1000 mH 400 mH/Ω
1000 μF 1000 mH 800 mH/Ω
Co
Lo
Lo/Ro
7 μF
207 mH
1 mH/Ω
73 μF
828 mH
5 mH/Ω
1000 μF 1000 mH 10 mH/Ω
Version Revision
V7 R0
9116-EMP - Version de produit 9116-003
Module 9116B2
Terminal 51-52, 51-53
Ui, Vmax
30 V
Ii, Imax
120 mA
Pi
900 mW
Ci
3 nF
Li
1 μH
Module 9116B2
Group
Terminal 51-54, 52-54
Uo, Voc
21.4 V
IIC or A,B
Io, Isc
93 mA
IIB or C,E,F
Po
650 mW
IIA or D,G
Module 9116B2
Group
Terminal 51-53
Uo, Voc
21.4 V
IIC or A,B
Io, Isc
1.1 mA
IIB or C,E,F
Po
8 mW
IIA or D,G
Module 9116B2
Group
Terminal 51-52
Uo, Voc
8.3 V
IIC or A,B
Io, Isc
0.2 mA
IIB or C,E,F
Po
0.4 mW
IIA or D,G
Module 9116B2
Group
Terminal 41,42,43,44
Uo, Voc
8.3 V
IIC or A,B
Io, Isc
13.1 mA
IIB or C,E,F
Po
27.3 mW
IIA or D,G
Prepared by:
PB
9116QF01
Co
Lo
Lo/Ro
0.16 μF
4 mH
54 μH/Ω
1.13 μF
16 mH 218 μH/Ω
4.15 μF
32 mH 436 μH/Ω
Co
Lo
Lo/Ro
0.16 μF 1000 mH
4 mH/Ω
1.13 μF 1000 mH 17 mH/Ω
4.15 μF 1000 mH 35 mH/Ω
Co
Lo
Lo/Ro
7 μF 1000 mH 100 mH/Ω
73 μF 1000 mH 400 mH/Ω
1000 μF 1000 mH 800 mH/Ω
Co
Lo
Lo/Ro
7 μF
207 mH
1 mH/Ω
73 μF
828 mH
5 mH/Ω
1000 μF 1000 mH 10 mH/Ω
Page:
2/4