The doors or windows are not closed.
There are heat sources inside the room.
Not cool enough
The air exhaust hose is not connected or
in cooling mode
blocked.
Temperature setting is too high.
Air inlet or outlet is blocked.
The ground is not level or not flat enough.
Check if there are any parts loose and
Noisy
vibrating.
The sound comes from the flowing of the
refrigerant inside the appliance.
Code "E0" on the
Communication faults between the main
digital display
PCB and the display board.
Code "E1" on the
Room temperature sensor failed.
digital display
Code "E2" on the
Evaporator temperature sensor failed.
digital display
Code "Ft" on the
Water-full warning
digital display
TECHNICAL DATA
Below data for your operating reference
Model
Rated voltage
Rated frequency
Cooling Rated input/current
Heating Rated input/current
Cooling capacity
Heating capacity
Moisture removal (L/H)
Air flow
Max. transmitting power
Frequency range
ERP INFORMATION
Trademark
Model identification
Sound power (cooling)
Sound power (heating)
Name of refrigerant
Rated power input for cooling (kW)
Make sure all the windows and doors
are closed.
Remove the heat sources if possible.
Connect or clean the air exhaust hose.
Reset the temperature.
Clean the air inlet or outlet.
Place the appliance on a flat, level
surface if possible.
Secure and tighten the parts.
It is normal.
Check the wire hardness of the display
board. Contact authorized service
technician for repair.
Replace the room temperature sensor.
Contact authorized service technician
for repair.
Replace evaporator temperature sensor.
Contact authorized service technician
for repair.
Drain out the water.
PAC-127033.1
220-240V
50Hz
1560W/6.9A
1300W/5.8A
4100W
3220W
1.5
410 m³ /h
20dBm
2412 - 2472MHz
Value
Emerio
PAC-127033.1
65 dB(A)
65 dB(A)
R290
1.56
- 16 -