6. Fan speed button
Press the fan speed button to select low speed, medium speed or high speed. The corresponding
indicator light of fan speed will turn on. By the remote control, users can also select the "AUTO" speed
under which the unit will adjust the fan speed automatically according to the room temperature.
Note: In drying mode, the fan speed cannot be selected. In heating mode, the fan speed will be adjusted
automatically between low and high according to the temperature around the air outlet.
7. Timer button
Auto-ON setting
When the appliance is OFF, press the timer button, the digital display will flash "00".
-
Press the timer increasing or decreasing button to select a desired auto-ON time from 1 to 24 hours.
-
The digital display will flash for several seconds, then the timer setting is confirmed. The timer-ON
indicator light will illuminate.
The appliance will automatically turn on once the select time passed.
-
Auto-OFF setting
When the appliance is ON, press the timer button, the digital display will flash "00".
-
Press the timer increasing or decreasing button to select a desired auto-OFF time from 1 to 24 hours.
-
The digital display will flash for several seconds, then the timer setting is confirmed. The timer-ON
indicator light will illuminate. The digital display will turn back to the temperature.
The appliance will automatically turn off once the select time has passed.
-
To change the timer, press the timer button and press the button "
set to 0 hour ("00"), the timer will be canceled and the timer-ON indicator light will turn off.
Note:
To shift the temperature unit between Celsius and Fahrenheit, long press the mode button for 3 seconds
when the appliance is on, or simply press the ℃/℉ conversion button on the remote control.
All the pictures are only for reference. Please see the real product for detailed information.
AUTOMATIC DEFROST
Under low room temperatures, the frost may build up at the evaporator during operation. The unit will
automatically start defrosting and the indicator light of the power button will blink. The defrost control
sequence is below:
When the unit is operating in cooling, heating or drying mode, and the evaporator coil temperature is below
-1°C, the compressor will stop operating for 10 minutes until the coil temperature rises up to 7°C. The unit will
then restart to work.
OVERLOAD PROTECTION
In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor
restarts.
DRAIN WATER
Manual drainage:
There is condensing water recycling hidden in this appliance. The condensing water is partly kept recycling
between the condenser and the water tray inside the appliance. When the water level rises to the upper level,
the water-full code "Ft" will be shown on the digital display to remind of draining water.
"/"
- 11 -