INSTRUCTIONS FOR THE INSTALLER
INSTALLATION
Electrical connection
Ensure that the voltage corresponds to that indicated in the plaque located on the oven door frame.
The cables for the connection to the mains must be protected from direct contact with the oven's metal casing.
The plaque must never be removed.
Attention: the ground connection must be compliant with law.
If using a fixed direct connection to the electrical network, it is necessary to provide a proper device which assures
the disconnection from the mains with a distance of contact opening which allows complete disconnection
in conditions of overvoltage category III, in accordance with the rules of installation.
Avoid using reductions or adaptors as they may cause overheating or burning.
After installation, carry out a brief oven check, following the instructions reported further down.
In case the appliance does not function, disconnect it from the mains and contact the after-sales assistance centre nearest to you.
Do not attempt to repair the appliance.
ATTENTION!
The manufacturer declines every responsibility for damages suffered by persons and things, caused by the non
compliance of the above prescriptions or deriving from the tampering of even a single part of the appliance and the
use of non original spare parts.
Oven positioning
The oven is pre-arranged for built-in purposes.
The sizes must respect the quota indicated in figures 1and 2.
The upper/rear part of the cabinet must have an opening of at least 80-90 mm deep, as indicated in figure 1.
Tighten the 4 screws by firstly inserting them inside the bush and then inside the frame (figures 1 Ref. A, B).
For installations underneath the "top" surface, ensure that the rear/lower part of the cabinet has an opening similar to that shown in figure 2.
(reference C).
Do not use the door as a lever to insert the oven inside the cabinet.
Do not put pressure on the open door.