ELECTRONIC IGNITION SYSTEM OPERATIONS
If the Electronic Ignition System fails to ignite, be sure there is gas flow by attempting to
match light your burners . Refer to "MAIN BURNER MANUAL IGNITION" . If match lighting
is successful, the problem lies is the electronic ignition .
m WARNING: All gas controls and supply valves should be in
the OFF position.
• Verify that the AA battery (alkaline only) is in good condition and installed correctly
(1) . Some batteries have a plastic protective wrap around them . This plastic must be
removed . Do not confuse this plastic with the battery label .
• Make sure the ignition wires are attached to igniter module properly . Refer to the
"IGNITER MODULE WIRE GUIDE" below .
• Make sure the ceramic igniter assembly is fully positioned into burner tube igniter
channel (2) . If properly positioned, you will hear a snap (3) .
• Make sure the Electronic Ignition button is working by listening and looking for sparks
at burner .
If the Electronic Ignition System still fails to light, contact the Customer Service
Representative in your area using the contact information on our web site. Log
onto www.weber.com.
◆
24
MAINTENANCE
A
1
4
Wire End & Terminal Color
Black (1)
Yellow (2)
Blue (3)
Green (4)
1
2
3
IGNITER MODULE WIRE GUIDE 330
D
C
B
3
2
1
2
4
3
Burner Tube
Left Burner (A)
Right Burner (B)
Center Burner (C)
Sear Burner (D)