for no reason must the smoke channel be used with a diameter lower than that of the neck of the outlet with
which the product is fitted;
each metre of horizontal route of the smoke channel causes a small leak of charge which should be
compensated for by raising the flue;
the horizontal section must never be higher than 2 m (UNI 10683-2005);
each bend of the smoke channel considerably reduces the draught of the flue which must be compensated
for by raising it suitably;
the UNI 10683-2005 Regulation –Italy requires that the bends or variations of direction must in no case be
greater than 2 including the emission into the flue.
Wanting to use the flue of a chimney or open furnace, it will be necessary to close the hood hermetically below the
inlet point of the smoke channel pos. A Picture 11.
If the flue is too large (e.g. cm 30x40 or 40x50) it is necessary to duct it with a stainless steel tube of at least 200 mm
of diameter, pos. B taking care to close the space between the tube itself and the flue immediately below the chimney
cap pos. C .
7196755 – EN
For any
further information, please contact your Dealer!
C - Plugging
B
A – Hermetic closure
Picture 11