Step 6. Remove the hanger pin, lock pin and set
screws from the top of the motor assembly. (Fig. 9)
Step 7. Route the safety cable and wires exiting
from the top of the fan motor through the collar
cover, canopy cover, canopy and then through the
ball/downrod. (Fig. 9)
Step 8. Align the holes at the bottom of the
downrod with the holes in the collar on top of the
motor housing (Fig. 9). Carefully insert the hanger
pin through the holes in the collar and downrod. Be
careful not to jam the pin against the wiring inside
the downrod. Insert the locking pin through the
hole near the end of the hanger pin until it snaps
into its locked position, as noted in the circle inset
of Fig. 9.
WARNING
FAILURE TO PROPERLY INSTALL
LOCKING PIN AS NOTED IN STEP 9
COULD RESULT IN FAN LOOSENING AND
POSSIBLY FALLING.
Step 9. Tighten two set screws on top of the fan
motor firmly. (Fig. 9)
Step 10. Place the downrod ball into the hanger
bracket socket.
5.
Step 11. Secure the safety cable to the building
structure with a wood screw. (wood screw not
supplied)
Supply wires
Downrod
Canopy
Canopy cover
Collar cover
Collar
Hanger pin
Figure 9
Safety cable
Pin in locked
position
Set screws
Lock pin