Installation - External & In-Line Blower
Preparation
NOTE! The device in this version
(with external blower) is equipped for
rear discharge of exhaust air. However,
if required, it is possible to have the
exhaust air discharged from the top.
This can be accomplished by carrying
out the steps indicated in the follow-
ing paragraphs; upon reaching step 4,
the blower plate must be rotated and
installed in the opposite direction.
The following instructions are for preparing the hood for use with an ex-
ternal or in-line blowers models CBE-1000 or PBN-1000A.
CAUTION: To reduce the risk of fire and electric shock, install this rangehood
only with remote blowers rated maximum 6.2 A.
For internal blower instructions please turn to page 11.
1. Remove the (2) screws securing the top
cover. See Fig.1
2. Remove the (6) screws securing the blo-
wer plate to the blower housing and
remove blower plate. See Fig.2
3. Remove the 8" round metal knockout
plate from the blower plate by using a
flat head screwdriver. See Fig.3
4. Install the plate with the outlet facing
the wall, inside the motor casing: carry
out the instructions at stage 2 in rever-
se order then use the screws provided
to complete installation. See Fig.4