Télécharger Imprimer la page

SKYLOTEC SECUPIN SPA-TYP-10-L Notice De Montage Et Guide D'utilisation page 16

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
When planning and installing anchor devices, please observe the BG information "Basic planning
principles for anchor devices on roofs" ( BGI 5164). The minimum clearance between anchor point and
roof edge must be at least 2.5 m.
When installing the anchor points, the load-carrying capacity of the subsoil must be considered.
Compatibility with similar systems is not guaranteed and and failure to comply with this specification may
pose a danger to life and limb.
Individual anchoring points serve for the fall protection of persons and not of objects or as transport
anchoring points.
Also consider approval and processing instructions of fasteners during installation. When using other
fasteners for installation, the system approval becomes invalid. The system may only be installed with
the fasteners supplied by Skylotec. All provided fasteners of a set must be installed. This means
that if 4 screw anchors (SPM-002) were supplied, all of them must be installed according to
installation instructions!
The minimum thickness of trapezoidal sheet metal must be 0.63 mm.
Avoid working above the anchor point (see operating instructions for lanyard).
Individual anchoring points must only be used by trained and instructed users. The employer or a technical
expert should instruct the user in how to correctly use the system.
Individual anchoring points must be inspected and maintained by a technical expert at annual intervals.
Check single anchor points and personal fall arrest equipment for defects before each use. Do not use
these products if you have any doubt about their functionality and ask a technical expert to check them.
Damaged anchor points and / or fasteners as well as other parts of the personal protective equipment
against falls may no longer be used. If necessary, the manufacturer or a technical expert has to check the
system or the personal protective equipment against falls.
After a fall, single anchor points must not be used again.
Bondings and screw connections incorrectly applied may become loose and compromise the safe
functioning of single anchor points! Improper repair, maintenance and / or manipulation of single anchor
points and their components represent a danger to life and limb. In this case, any warranty will become
void and any liability by SKYLOTEC GmbH is excluded.
This product may only be used with lanyard elements (in conformity with EN 362) and personal fall arrest
equipment.
When using additional personal protective equipment, you have to comply with relevant operating
instructions and applicable regulations .
4.
GENERAL ASSEMBLY REQUIREMENTS
All parts must be cleaned of dirt before installation. Contact of the system with aggressive substances and
chemicals as well as mortar, cement or similar materials should be avoided. Mortar residue and / or other
contaminants must be removed immediately to ensure proper functioning of the product. The product must be
installed strictly in accordance with the manufacturer's installation instructions. Deviations are not permitted.
Only original SKYLOTEC components may be used for installation and replacement. The combination with
components or elements by other manufacturers or suppliers may present a risk to life and limb! The
components should be treated with care and must not be used improperly. A set of identification labels must be
attached to each entry and exit point. For existing structures, the following safety devices are required for
installation: Harnesses according to EN 361 and separate safety ropes with energy absorbers according to EN
354/355.
Since structurally anchored attachement points/devices are no longer subject to the PPS Directive,
they may no longer be CE marked. In Germany the building inspectorate approval is required for such
products. In Europe, different national regulations apply to these products; under certain
circumstances a specific approval is required.
MAT-MA-0023-EN SECUPIN
23/01/2015
Page 3 of 12

Publicité