Télécharger Imprimer la page

Stiebel Eltron CNS 100-1 Trend Utilisation Et Installation page 8

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
Settings
7.4.2 Time programs
Three time programs are available. Time programs Pro1 and Pro2
are pre-configured at the factory. Time program Pro3 can be set
according to your individual requirements.
Display
Description
Pro1
Time program "Daily"
- Repeated: Monday to Sunday
Pro2
Time program "Weekdays"
- Repeated: Monday to Friday
Pro3
Time program "User defined"
- up to 14 comfort phases, freely configurable
Note
To use a time program, select the required time pro-
gram from the standard menu (See section 7.3, "Standard
menu", pg. 7).
Note
Ensure the day of the week and the time are set correctly
when setting the time programs.
Note
The following applies to all time programs (Pro1, Pro2,
Pro3):
If the end time is later than 23:59 h, the end time will
automatically be moved to the next day of the week. The
comfort phase is maintained past midnight and will end
on the next day at the set end time.
Time programs Pro1 and Pro2
You can specify the comfort mode start and end times with time
programs Pro1 and Pro2. During this time period, the heater heats
to the set comfort temperature. Outside this specified time period,
the heater operates in night mode. This results in a comfort phase
and a night phase, which are repeated daily (Pro1) or on every
working day (Pro2).
Theses phases are factory-set as follows:
- 08:00 am - 10:00 pm: Comfort mode
- 10:00 pm - 08:00 am: Night mode
Note
When time program Pro2 is enabled, the heater operates
during weekends exclusively in night mode.
To adapt time programs Pro1 and Pro2 according to your needs,
proceed as follows:
In the configuration menu, use "+" and "–" to call up the re-
quired time program.
Press "OK".
The start time for comfort mode is displayed.
Use "+" and "–" to set the required start time.
Press "OK".
The end time for comfort mode is displayed.
Use "+" and "–" to set the required end time.
Press "OK" to save.
8
| CNS Trend & CNS Plus
Time program Pro3
You can use time program Pro3 to specify up to 14 separate com-
fort phases which are repeated weekly.
To configure a comfort phase in time program Pro3, proceed as
follows:
In the configuration menu, use "+" and "–" to call up time
program Pro3.
Press "OK".
The display shows "3---".
Press "OK".
A day of the week or a group of days is displayed.
Use "+" and "–" to select the required day or group of days.
Press "OK".
The start time for comfort mode is displayed.
Use "+" and "–" to set the required start time.
Press "OK".
The end time for comfort mode is displayed.
Use "+" and "–" to set the required end time.
Press "OK".
Comfort phase "3-01" has been configured.
To configure a further comfort phase, use "+" and "–" in time
program Pro3 to select display "3---". Proceed as described
above.
Note
To reset the selected comfort phases, activate parame-
ter P4.
Please note that activating parameter P4 resets all
time programs (Pro1, Pro2, Pro3) to the factory set-
ting.
7.4.3 Parameters
You can call up the following parameters:
Display
Description
P1
Room temperature offset
P2
Time format
P3
Temperature display units
P4
Reset the time programs (Pro1, Pro2, Pro3).
P5
Reset relative heating time
To change the value of a parameter, use "+" and "–" to call up the
relevant parameter. Press "OK".
As soon as the "Editable parameter" symbol appears, you can
change the parameter value with "+" and "–". Press "OK" to save
the selected value.
P1: Room temperature offset
Uneven temperature distribution in the room can result in a differ-
ence between displayed actual temperature I1 and the room tem-
perature you measure. To compensate for this difference, a room
temperature offset of ±5 °F (±3 °C) can be set via parameter P1.
Example: The heater indicates I1 = 70 °F (21.0 °C). You have mea-
sured a room temperature of 68 °F (20.0 °C). There is a difference
of 2 °F (1.0 °C).
To compensate for the difference, select an offset of P1 = -2.0
(-1.0).
Options
±3 °C | ±5 °F
12 h | 24 h
°C | °F
on | off
on | off
www.stiebel-eltron-usa.com

Publicité