OPERATION
Settings
Symbol
Description
Room temperature display
Editable parameter:
The parameter shown can be changed using "+" and "–".
Days of the week:
1 = Monday, 2 = Tuesday ... 7 = Sunday
6.2
Standby mode
Material losses
In standby mode, the heater will not produce heat under
any circumstances. Frost protection is deactivated until
the heater is taken out of standby mode.
To switch on the programming unit, press "Standby". The
standard display appears.
To put the programming unit and the heater into standby
mode, press "Standby". The display shows "- - - -".
7.
Settings
7.1
Operating lock
To lock or unlock the user interface, press and hold
"+" and "–" simultaneously for 5 seconds.
7.2
Standard display
The standard display is continuously shown. If no user input is
detected for longer than 20 seconds while in the menu, the device
automatically switches to the standard display.
The standard display shows the current room set temperature, as
well as the "Editable parameter" symbol. You can use "+" and "–"
to change the room set temperature.
If the room set temperature corresponds to one of the values
established for the comfort or night mode temperature settings,
the symbol for the corresponding operating mode (comfort mode,
night mode) appears in the menu bar.
The room set temperature can also be changed manually with a
time program active. The changed set room temperature is main-
tained until the next programmed switching point is reached.
7.3
Standard menu
To access the standard menu, briefly press "Menu". You can now
call up the following menu items:
Display
Description
Select day of the week and time
www.stiebel-eltron-usa.com
Display
Description
Select comfort temperature setting
The comfort temperature must be set at least 1 °F (0.5 °C)
higher than the night mode temperature.
Select night mode temperature setting
The night mode temperature must be set at least 1 °F (0.5 °C)
lower than the comfort temperature.
Switch "Window open detection" function on and off
Select time program (Pro1, Pro2, Pro3, off)
Switch "Adaptive start" function on and off
To change the setting of a menu item, call the relevant menu item
up using "+" and "–". Press "OK".
As soon as the "Editable parameter" symbol appears, you can
change the setting of the menu item with "+" and "–". Press "OK"
to save the setting.
To exit the standard menu, press "Menu". The standard display
appears.
7.4
Configuration menu
Display
Description
I1-I2
Actual values
Pro1-Pro3 Time programs
P1-P5
Parameter
In the configuration menu, you can call up actual values, set time
programs and adjust parameters.
To access the configuration menu, press and hold "Menu". After
approx. 3 seconds, actual value I1 is displayed.
Use "+" and "–" to switch between the individual actual values,
time programs, and parameters.
To exit the configuration menu, press "Menu". The standard dis-
play appears.
7.4.1 Actual values
The following actual values can be called up:
Display
Description
I1
Actual room temperature
I2
Relative heating time
(The counter can be reset via parameter P5.)
Note
The counter for relative heating time (I2) counts in com-
plete hours how long the heater heats for. When the
heater is switched off, any heating phase of less than
60 minutes is not recorded.
Unit
[°C] | [°F]
[h]
CNS Trend & CNS Plus |
7