6.
MODE SElECT (ChARGE / DISChARGE / CyClE)
If all charge- /discharge parameters have been set-up, then the charge-/discharge mode
can be selected. To do this, use the "DEC" or "INC" buttons to select "CHARGE" or
"DISCHARGE". Then press "ENTER" for 2 seconds. The screen changes. It is now mode
selection screen. The upper section will show all the important battery data. The l o w e r
section of the top screen allows the required process to be selected.
on. To change the process to be used for charging,
navigate to "CHARGE" and press the "ENTER" button for 2 seconds. Now The Mode
screen as described above will appear. After setting up the mode, the "ESC" button is
pressed. Should the mode need also be set for discharge, proceed as for "CHARGE".
When both modes have been set up, navigate to "CYCLE" and hold the "ENTER" button
down. The process starts and the selected modes will be used.
• NUMBER OF CYCLES • DELAY
(max. 10 cycles)
Operating Instructions
Power Peak ® Twin EQ-BID
The "DEC" or "INC" buttons must be pressed to select.
Thus, the following charge options may be chosen for NiCd
and NiMH batteries:
• AUTOMATIC • LINEAR
• NORMAL • REFLEX
There is no choice for Lithium or Pb batteries. The
charging process uses the well-known CC-CV method.
Highlighting and activating "DISCHARGE", the following
discharge processes are available for selection for NiCd
and NiMH batteries:
• AUTOMATIC • LINEAR
• NORMAL
There is no choice for Lithium or Pb batteries. The
discharging process uses the well-known LINEAR method.
The screen shown here has the "CYCLE" process high-
lighted, here the operation sequence as well as the number
of cycle and the pause in between cycles can be program-
med:
• Charge>Discharge • Discharge>Charge
The AUTOMATIC mode is set as default in CYCLE operati-
19