Lamborghini Caloreclima TAURA 32 MCS Notice D'utilisation page 26

Chaudière murale à gaz chambre de combustion étanche, pour la production d'eau chaude sanitaire et le chauffage

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
Connection with separate pipes
1. Completely define the layout of the system of split flues, including accessories and outlet end pieces.
2. Refer to the following table and identify the losses in
installation.
3. Check that the total sum of the losses is less than or equal to the maximum permissible value: 35
Table of pipe and accessory losses
Component
Accessories Ø 80
Pipe Ø 80 male-female
Bend 45° Ø80
Bend 90° Ø80 male-female
Condensate collection cup coupling
Windproof end piece for products of combustion Ø 80 mm
Suction protection air end piece Ø 80
Rooftop outlet 80/125 + TEE reduction for separate ducts
Connection with separate pipes
Remove the air inlet closing cap. Fit the two flanged sections Ø80, with their seals. If necessary, install the diaphragm
under the air inlet section
Caution: use solely Lamborghini Caloreclima fume suction/outlet kits
26
m of each component according to the position of
eq
Drawing
Air
Remove
Fumes
the plug
Air diaphragm
** Air suction Ø 80
Losses eq
m
Suction
Outlet
Vertical
Horizontal
1
1
1,2
2,2
1,5
2,5
/
3
/
/
2
/
/
12
Taura 32 MCS
m.
eq
Outlet
2
/
5
/