making holes in accordance with the diagram shown in
(fi g. 1). To fi t the appliance correctly, align the front panel of
the cooker hood with the cabinet door and adjust spacer L
using screws P (fi g. 2A), then ensure the appliance meets the
cabinet at the rear.
• Extraction through an outside wall
The appliance expels the fumes through an outside wall or
a duct. It is necessary to buy a telescopic pipe in accordance
with the standards in use (infl ammable) and connect it to
fl ange B (Fig 3).
• Recirculation
To transform the cooker hood from the extraction version
to the re circulating one ask your supplier for an activated
carbon fi lter.
The fi lter must be fi tted to the extracting group cooker hood
in the centre of the fan grille by twisting it by 90 degrees until
it is gripped securely (Fig 6). For this operation remove the
anti-grease fi lter(s) G (Fig 5). The clean air is returned into the
room through a connecting tube passing inside the cupboard
and connected to the ring B (fi g 4).
USE AND MAINTENANCE
• We recommend that the cooker hood is switched on before
any food is cooked. We also recommend that the appliance is
left running for 15 minutes after the food is cooked, in order
to thoroughly eliminate all contaminated air.
The eff ective performance of the cooker hood depends on
constant maintenance; the anti-grease fi lter and the active
carbon fi lter both require special attention.
• The anti-grease fi lter is used to trap any grease particles
suspended in the air, therefore is subject to saturation (the
time it takes for the fi lter to become saturated depends on
the way in which the appliance is used).
- To prevent potential fi re hazards, the anti-grease fi lters
should be washed a minimum of every 2 months (it is
possible to use the dishwasher for this task).
- After a few washes, the colour of the fi lters may change.
This does not mean they have to be replaced.
If the replacement and washing instructions are not followed,
the anti-grease fi lters may present a fi re hazard.
• The active carbon fi lters are used to purify the air which
is released back into the room. The fi lters are not washable
or re-usable and must be replaced at least once every four
months.
The active carbon fi lter saturation level depends on the
frequency with which the appliance is used, the type of
cooking performed and the regularity with which the anti-
grease fi lters are cleaned.
• Clean the cooker hood frequently, both inside and outside,
using a cloth which has been dampened with denatured
alcohol or neutral, non-abrasive liquid detergents.
• The light on the cooker hood is designed for use during
cooking and not for general room illumination. Extended
use of the light reduces the average duration of the bulb.
• Replacing halogen light bulbs (Fig. 7).
To replace the halogen light bulbs B, remove the glass pane
C using a lever action on the relevant cracks.
Replace the bulbs with new ones of the same type.
Caution: do not touch the light bulb with bare hands.
• Commands: (Fig.2B)
Push-button A = on/off lights switch
Push-button B = on/off cooker hood switch. The appliance
switches on at speed level 1, If the cooker hood is on depress
the push-button for 2 sec. to switch off the cooker hood. If
the cooker hood is at speed level 1 it will not be necessary
to depress the push-button to switch the cooker hood off .
Decreases the motor speed.
Display C = indicates the motor speed level selected and
activates the timer.
Push-button D = switches on the cooker hood. Increases the
motor speed. Touching the key at 3rd speed, the intensive
function runs for 10' , then the appliance go back to work at the
original speed. During this function the display blinks.
Key E = The Timer times the functions on activation for 15
minutes, after which they are switched off . The Timer is deac-
tivated by re-pressing Key E. When the Timer is activated the
decimal point must fl ash on the display. The Timer cannot be
activated if the intensive speed is functioning.
The "clean air" function is activated by pressing key E for 2
seconds when the appliance is switched off . This switches the
motor on for 10 minutes every hour at the fi rst speed. During
functioning a rotary movement of the peripheral segments
must be visualised on the display. When this time has passed
the motor switches off and the fi xed letter "C" must be visu-
alised on the display until the motor re-starts after 50 minutes
for another 10 minutes and so on. Press any key apart from
the light keys to return to normal functioning. Press key E to
deactivate the function.
• Active carbon/grease fi lter saturation:
- When display item C fl ashes, at a speed where it alternates
with the letter F (e.g. 1 and F), the grease fi lters must be
washed.
- When display item C fl ashes, at a speed where it alternates
with the letter A (e.g. 1 and A), the carbon fi lters must be
replaced.
After the clean filter has been positioned correctly, the
electronic memory must be reset by pressing button A for
approximately 5 seconds, until the indication F or A shown
on the display C stops fl ashing.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR
EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE
WARNINGS.