Note: to ensure the correct installation of the product, it is recommended to tape the pipes using an adhesive with the following
characteristics:
- soft elastic PVC film, with an acrylic-based adhesive
- compliant with DIN EN 60454 regulations
- flame retardant
- excellent resistance to wear
- resistant to temperature fluctuations
- can be used at low temperatures
ELECTRICAL CONNECTION
Fig. 3
● Disconnect the device from the electric power supply. ● Installation must be carried
out by professionally qualified personnel with knowledge of the regulations in force for
installation and safety. ● The manufacturer denies all liability to persons, animals or
property if the guidelines provided in this chapter are not followed. ● The power cable
must be long enough to allow the hob to be removed from the worktop. ● Make sure
that the voltage on the serial number data plate on the bottom of the device corresponds
to that of the domestic environment where it will be installed. ● Do not use extension
leads. ● The earth power cable must be 2cm longer than the other cables. ● If the
electrical appliance is not supplied with a power cable, use one with a minimum
conductor diameter of 2.5 mm2 for power up to 7200 Watt; for higher power levels, the
diameter must be 4 mm2. ● The temperature must not reach 50°C above room
temperature anywhere along the cable. ● The appliance is intended for permanent
connection to the power supply.
Fig. 3b/3c
Note: to connect the appliance using the optional single phase connection the existing
cable must be removed and replaced with another type (not supplied) having the
following specifications:
single phase connection:H05V2V2-F 3G4 cable
Fig. 3a
● Please note! Before reconnecting the circuit to the mains power supply, make sure
that it is working correctly, always check that the power cable is correctly installed. ●
Please note! The interconnection cable must be replaced by the authorised technical
support service or by a person with similar qualifications.
Note : the product is equipped with a Power Limitator function, which allows a maximum
power limit to be set
The limit must be set at the time of the product's connection to the electrical network or
when the electrical network itself is reconnected (within the following 2 minutes). For the
Power Limitation setting sequence, see the Operation section of this manual.
59