Télécharger Imprimer la page

Aqua Medic easy line 90/150 Mode D'emploi page 9

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Art.-No.
Pict.-No.
U605.06
2
U605.01
3
U605.50
4, 7 u. 9
U700.25-32
5 / 7
U605.60
8
U605.65
8
U700.25-4
9
U700.25-31
10
U610.06
11
U610.01
11
2.
Set-Up
To fix the unit to a wall, disconnect the two wall brackets from the module and fix them directly on
the wall or a mounting plate - preferably near a tap connection. Press module into the brackets -
ready.
Then, mount the membrane and connect the tubes. To avoid any failures, follow the instructions
carefully:
The connections of the unit are (please refer to Fig. 1):
Note: Before taking the unit into first operation, rinse the pre-filter and then attach it to
the reverse osmosis module!
9
Article
Sediment filter 5 µm with fittings for easy line
Carbonate prefilter with fittings for easy line
Membrane housing
Fitting 1/8" 90° white
Membrane 90 l/day
Membrane 150 l/day
O-ring 55 x 4
Fitting 1/4" white
Flushing valve 90 l/day
Flushing valve 150 l/day
Tube fittings:
1. Take the blue lock ring off.
2. Put the hose to a complete stop into the fitting.
3. Refit the lock ring.
4. Pull the hose back as a test that it was placed firmly.
Release the plug connection:
1. Take the blue lock ring off.
2. Squeeze the ring at the fitting. Now, you can pull the tube out.
3. Please don't forget to refit the lock ring.

Publicité