For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No
Basic Models:
Name:
Model ID (Stock Ref.) :
Declared as: RVU or NRVU/UVU or BVU
Speed Drive
Type HRS (Recuperative, Regenerative, None)
Thermal Eff: [ (%), NA(if none)]
Nominal Flow Rate (m3/s)
Effective Elec. Power Input (kW): (@Nom.Flow Rate&Ext. Pressure)
SFPint [W/(m3/s)]
Face Velocity (m/s) @ Design Flow Rate
Nominal External Pressure: (Δp
) in Pa
s, ext
Internal Pressure Drop of Ventilation Components (Δp
Additonal Internal Press. Drop of Non-Ventilation Comp.: Δp
(Pa)
Static Eff. of fans used in accordance with Regulation (EU) No
327/2011;
Declared: -Max Internal & External Leakage Rates(%) for BVUs or
carry over (for regenerative heat exchangers only),
-&Ext. Leakage Rates (%) for Ducted UVUs;
Energy Performance, preferably energy classification, of the Filters
(declared information about the calculated AEC)
Filter Warning (RVU)
For UVUs (Instructions Install Grilles Façade)
Internet Address (for Disassembly Instructions)
PRODUCT FICHE
1254/2014)
Vent-Axia
ACM 100 -
Lineair 100-
17104010D
8000000070
NRVU/UVU
Multi Speed
None
N/A
0.06
0.02
N/A
N/A
71
) in Pa;
N/A
s,int
s,add
N/A
TBC
N/A
N/A
No
In F&W
www.vent-axia.com www.vent-axia.com www.vent-axia.com www.vent-axia.com www.vent-axia.com
18
Vent-Axia
Vent-Axia
ACM 125 -
ACM150 -
Lineair 125-
Lineair 150-
17105010D
17106010C
8000000072
8000000074
NRVU/UVU
NRVU/UVU
Multi Speed
Multi Speed
None
None
N/A
N/A
0.07
0.11
0.03
0.05
N/A
N/A
N/A
N/A
74
92
N/A
N/A
N/A
N/A
TBC
TBC
N/A
N/A
N/A
N/A
No
No
In F&W
In F&W
Vent-Axia
Vent-Axia
ACM160 -
ACM200 -
Lineair 150-
17107010B
17108010C
8000000074
NRVU/UVU
NRVU/UVU
Multi Speed
Multi Speed
None
None
N/A
N/A
0.11
0.18
0.05
0.10
N/A
N/A
N/A
N/A
92
167
N/A
N/A
N/A
N/A
TBC
TBC
N/A
N/A
N/A
N/A
No
No
In F&W
In F&W