Safety instructions
Please follow the national rules and
–
regulations for fuel spray jets of the re-
spective country.
Please follow the national rules and
–
regulations for accident prevention of
the respective country. Fuel spray jets
must be tested regularly and the results
of these tests must be documented in
writing.
Proper use
Use this high pressure cleaner exclusively
for
Cleaning using low pressure jet and de-
–
tergent (for e.g. for cleaning machines,
cars, buildings, tools),
For cleaning using high pressure jet
–
without detergent (for e.g. for cleaning
facades, terraces, garden appliances).
For stubborn dirt, we recommend the use of
the dirt blaster as a special accessory.
Safety Devices
Safety devices serve for the protection of
the user and must not be put out of opera-
tion or bypassed with respect to their func-
tion.
Overflow valve
While reducing the water supply/quantity
regulation at the pump head, the overflow
valve opens and part of the water flows
back to the pump suck side.
Pressure switch
If the lever on the trigger gun is released
the pressure switch turns off the pump, the
high-pressure jet is stopped. If the lever is
pulled the pump is turned on again.
The overflow valve and pressure switch are
set and sealed at the factory. Setting only
by customer service.
16
Environmental protection
The packaging material can be
recycled. Please do not place
the packaging into the ordinary
refuse for disposal, but arrange
for the proper recycling.
Old appliances contain valuable
materials that can be recycled.
Please arrange for the proper
recycling of old appliances. Bat-
teries, oil, and similar substanc-
es must not enter the
environment. Please dispose of
your old appliances using ap-
propriate collection systems.
Notes about the ingredients (REACH)
You will find current information about the
ingredients at:
www.kaercher.com/REACH
Before Startup
Check the contents of the pack before
–
unpacking.
In case of transport damage inform ven-
–
dor immediately
Check oil level
Read the oil level display when the de-
vice is not running. The oil level must be
between the two markers on the oil res-
ervoir.
Activate deaeration of oil container
Unscrew the fastening screws of the
device hood; remove the device hood.
Cut off tip of oil container cover
Fasten the device hood.
– 2
EN
Unpacking