Télécharger Imprimer la page

Fayat Group DYNAPAC SD1800W Utilisation Et Entretien page 225

Publicité

KWP
SPN
FMI
896
523723
11
897
523632
16
898
523632
18
899
523632
0
900
523632
1
903
4365
0
905
3241
0
906
3241
1
908
3361
7
914
523720
2
915
523720
2
916
523721
2
917
523721
2
918
523981
11
919
523330
14
925
523720
8
926
523720
8
927
523721
11
928
523722
8
929
523722
8
930
523721
8
931
523721
8
932
29
3
935
91
3
Code
Error Identification
8-7-4
Detection of AdBlue filled SCR system in
Init-State
8-7-5
Pump pressure SCR metering unit too
high
8-7-6
Pump pressure SCR metering unit too
low
8-7-7
Pressure overload of SCR-System
8-7-8
Pressure build-up error SCR-System
8-8-1
Urea tank temperature too high
8-8-3
Sensor SCR catalyst upstream tempera-
ture too high; plausibility error
8-8-4
Sensor SCR catalyst upstream tempera-
ture too low; plausibility error
8-8-6
AdBlue dosing valve blocked (SCR)
6-9-0
Urea supply module heater temperature;
plausibility error
6-9-0
Urea supply module heater temperature;
plausibility error
6-8-9
Urea supply module heater temperature;
plausibility error
6-8-9
Urea supply module heater temperature;
plausibility error
Urea-tank without heating function (heat-
ing phase)
1-3-1
Immobilizer status; fuel blocked
6-9-0
Urea supply module heater temperature;
signal disrupted
6-9-0
Urea supply module heater temperature;
signal disrupted
6-8-9
Urea supply module temperature mea-
surement not available
6-9-1
Urea supply module PWM signal; signal
disrupted
6-9-1
Urea supply module PWM signal; signal
disrupted
6-8-9
Urea supply module temperature; signal
disrupted
6-8-9
Urea supply module temperature; signal
disrupted
1-2-6
Handthrottle; signal out of range, short
circuit to battery
2-2-6
Sensor error accelerator pedal; signal
range check high
Short Text Detail
Detection of AdBlue filled SCR system in Init-
State
Pump pressure SCR metering unit too high
Pump pressure SCR metering unit too low
Pressure overload of SCR-System
Pressure build-up error SCR-System
Urea tank temperature too high
Sensor SCR catalyst upstream temperature
too high; plausibility error
Sensor SCR catalyst upstream temperature
too low; plausibility error
AdBlue dosing valve blocked (SCR)
Sensor urea supply module heater tempera-
ture; plausibility error (normal condition)
Sensor urea supply module heater tempera-
ture; plausibility error (cold start condition)
Sesnor urea supply module temperature; plau-
sibility error (normal condition)
Sensor urea supply module temperature; plau-
sibility error (cold start condition)
Urea-tank without heating function (heating
phase)
Immobilizer status; fuel blocked
Urea supply module heater temperature; duty
cycle in failure range
Urea supply module heater temperature; duty
cycle in invalid range
Urea supply module temperature measurement
not available
Urea supply module PWM signal; period out-
side valid range
Detect faulty PWM signal from Supply Modul
Urea supply module temperature; duty cycle in
failure range
Urea supply module temperature; duty cycle in
invalid range
Handthrottle idle validation switch; short circuit
to battery
Sensor error accelerator pedal; signal range
check high
D 23.18 61

Publicité

loading

Ce manuel est également adapté pour:

913