Télécharger Imprimer la page

Fayat Group DYNAPAC SD1800W Utilisation Et Entretien page 216

Publicité

KWP
SPN
FMI
417
171
3
418
171
4
419
190
8
420
190
12
421
190
2
422
190
8
423
190
12
424
703
5
425
703
12
426
703
3
427
703
4
450
975
5
451
975
12
452
975
3
453
975
4
455
975
5
456
975
12
457
975
3
458
975
4
460
1639
0
461
1639
1
462
523602
0
463
523602
0
464
97
3
D 23.18 52
Code
Error Identification
3-1-2
Sensor error environment temperature;
signal range check high
3-1-2
Sensor error environment temperature;
signal range check low
2-1-2
Speed detection; out of range, signal dis-
rupted
2-1-2
Speed detection; out of range, signal dis-
rupted
2-1-3
Offset angle between crank- and cam-
shaft sensor is too large
2-1-2
Speed detection; out of range, signal dis-
rupted
2-1-2
Speed detection; out of range, signal dis-
rupted
1-4-2
Engine running lamp; open load
1-4-2
Engine running lamp; powerstage over
temperature
1-4-2
Engine running lamp; short circuit to bat-
tery
1-4-2
Engine running lamp; short circuit to
ground
2-2-8
Fan control; open load
2-2-8
Fan control; internal error
2-2-8
Fan control; short circuit to battery
2-2-8
Fan control; short circuit to ground
2-2-8
Fan control; open load
2-2-8
Fan control; internal error
2-2-8
Fan control; short circuit to battery
2-2-8
Fan control; short circuit to ground
2-2-8
Sensor error fan speed; signal range
check high
2-2-8
Sensor error fan speed; signal range
check low
2-2-8
Fan control; out of range, system reac-
tion initiated
2-2-8
Fan control; out of range, system reac-
tion initiated
2-2-8
Sensor error water in fuel; signal range
check high
Short Text Detail
Sensor error environment temperature; signal
range check high
Sensor error environment temperature; signal
range check low
Sensor camshaft speed; disturbed signal
Sensor camshaft speed; no signal
Offset angle between crank- and camshaft sen-
sor is too large
Sensor crankshaft speed; disturbed signal
Sensor crankshaft speed; no signal
Engine running lamp; open load
Engine running lamp; powerstage over temper-
ature
Engine running lamp; short circuit to battery
Engine running lamp; short circuit to ground
Digital fan control; open load
Digital fan control; powerstage over tempera-
ture
Digital fan control; short circuit to battery
Digital fan control; short circuit to ground
Fan actuator (PWM output); open load
Fan actuator (PWM output); powerstage over
temperature
Fan actuator (PWM output); short circuit to bat-
tery
Fan actuator (PWM output); short circuit to
ground
Sensor error fan speed; signal range check
high
Sensor error fan speed; signal range check
low
High fan speed; warning threshold exceeded
High fan speed; shut off threshold exceeded
Sensor error water in fuel; signal range check
high

Publicité