KWP
SPN
FMI
755
523919
0
758
523919
1
761
523919
3
762
523919
4
763
523920
2
765
523920
0
768
523920
1
770
523920
3
771
523920
4
776
102
3
777
102
4
791
411
0
792
411
1
793
411
11
794
411
2
795
411
3
796
411
4
805
524025
14
807
3253
2
809
3251
0
812
3251
1
D 23.18 58
Code
Error Identification
6-9-4
Physical range check high for airpump
pressure; shut off regeneration
6-9-4
Physical range check low for airpump
pressure; shut off regeneration
6-9-4
Sensor error airpump pressure; signal
range check high
6-9-4
Sensor error airpump pressure; signal
range check low
7-1-6
Sensor exhaustgas back pressure; plau-
sibility error
7-1-6
Physical range check high for exhaust-
gas back pressure burner; shut off
regeneration
7-1-6
Physical range check low for exhaustgas
back pressure burner; shut off regenera-
tion
7-1-6
Sensor error exhaustgas back pressure
burner; signal range check high
7-1-6
Sensor error exhaustgas back pressure
burner; signal range check low
2-2-3
Sensor error charged air pressure; signal
range check high
2-2-3
Sensor error charged air pressure; signal
range check low
6-9-3
Physical range check high for differential
pressure Venturiunit (EGR)
6-9-3
Physical range check low for differential
pressure Venturiunit (EGR)
6-9-3
Sensor differential pressure Venturiunit
(EGR); plausibility error
6-9-3
Sensor differential pressure Venturiunit
(EGR); CAN signal invalid
6-9-3
Sensor error differential pressure Ventu-
riunit (EGR); signal range check high
6-9-3
Sensor error differential pressure Ventu-
riunit (EGR); signal range check low
Particulate filter; regeneration not suc-
cesful
6-9-2
Sensor differential pressure (DPF); plau-
sibility error
6-9-2
Physical range check high for differential
pressure (DPF); shut off regeneration
6-9-2
Physical range check low for differential
pressure (DPF); shut off regeneration
Short Text Detail
Physical range check high for airpump pres-
sure; shut off regeneration
Physical range check low for airpump pressure;
shut off regeneration
Sensor error airpump pressure; signal range
check high
Sensor error airpump pressure; signal range
check low
Sensor exhaustgas back pressure; plausibility
error
Physical range check high for exhaustgas back
pressure burner; shut off regeneration
Physical range check low for exhaustgas back
pressure burner; shut off regeneration
Sensor error exhaustgas back pressure burner;
signal range check high
Sensor error exhaustgas back pressure burner;
signal range check low
Sensor error charged air pressure; signal range
check high
Sensor error charged air pressure; signal range
check low
Physical range check high for differential pres-
sure Venturiunit (EGR)
Physical range check low for differential pres-
sure Venturiunit (EGR)
Sensor differential pressure Venturiunit (EGR);
plausibility error
Sensor differential pressure Venturiunit (EGR);
CAN signal invalid
Sensor error differential pressure Venturiunit
(EGR); signal range check high
Sensor error differential pressure Venturiunit
(EGR); signal range check low
Particulate filter; regeneration not succesful
Sensor differential pressure (DPF); plausibility
error regarding signal offset
Physical range check high for differential pres-
sure (DPF); shut off regeneration
Physical range check low for differential pres-
sure (DPF); shut off regeneration