MAINTENANCE
Accidental start-up. Disconnect the spark plug boot from
the spark plugs when performing maintenance on the
generator.
MAINTENANCE SCHEDULE
Regular maintenance will improve performance and
extend the service life of the generator. Follow the hourly
or calendar intervals, whichever occurs first. More frequent
service is required when operating in adverse conditions
as noted below.
Before Each Use
Check engine oil
Check air filter
After First 20 Hours or First Month
Change engine oil
After 50 Hours or Every 3 Months
Clean air filter
After 100 Hours or Every 6 Months
Change engine oil
Inspect/clean spark arrestor
Inspect/clean spark plug
Replace fuel filter
Clean float bowl
After 300 Hours or Every Year
Replace spark plug
Replace air filter
Replace fine oil filter
Inspect/adjust valve clearance
Every 2 years
Replace fuel pipe
1
Change oil every month when operating under heavy
load or in high temperatures.
2
Clean more often under dirty or dusty conditions.
Replace air filter if it cannot be adequately cleaned.
3
Recommend service to be performed by authorized
Westinghouse service dealer.
MAINTENANCE REPLACEMENT PARTS
Description
Air filter
Oil drain bolt crush washer
Battery, 18 AH
Fuel filter
Spark plug
Spark arrester
22 | Westinghouse Outdoor Power Equipment
1
2
1
3
3
Part Number
5061
94242
511092
516401
97108 (F7TC)
6859
AIR FILTER MAINTENANCE
The air filter must be cleaned after every 50 hours of use or
six months (frequency should be increased if the generator
is operated in a dusty environment).
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. Release the four clips then remove the air filter cover.
3. Remove the air filter and clean using compressed air.
DO NOT submerge the filter in liquids or add oil.
4. Install the air filter in the housing, making sure it is
correctly oriented and seated in the housing.
5. Install the air cleaner cover and secure with the cover
clips.
ENGINE OIL LEVEL CHECK
Avoid skin contact with engine oil. Wear protective
clothing and equipment. Wash all exposed skin with
soap and water.
Always use the specified engine oil. Failure to use the
specified engine oil can cause accelerated wear and/or
shorten the life of the engine.
When using the generator in dusty conditions or in
extremely hot weather, change the oil more frequently.
Ambient air temperature will affect engine oil performance.
Change the type of engine oil used based on weather
conditions.