CONTROL PANEL COMPONENTS
18
17
16
1.
Push-Button START/STOP: Push once to
automatically start the engine. Push again to stop
the engine.
2.
Battery Switch: Turns battery ON and OFF. Must be
ON before electric or remote start.
3.
30 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
L14-30R receptacle to 30 amps.
4.
Low Idle Switch: Low Idle minimizes fuel
consumption, noise, and engine wear by lowering
the engine RPM during intermittent use. See LOW
IDLE section for important use considerations.
5.
Battery Charging Port: Used to charge the battery
with the included battery charger.
6.
USB Ports: Two-port 5V/2.1A USB outlet. Accepts
Type A USB plugs.
7.
VFT Data Center: Displays voltage, frequency,
total hour meter, and run/maintenance timer.
8.
Main Circuit Breaker: The main circuit breaker
controls total output of all outlets to protect the
generator from overload or short circuit.
9.
20 Amp AC Circuit Breakers: Circuit breakers
limits the current that can be delivered through
each NEMA 5-20R receptacle to 20 Amps.
10. Ground Terminal: The ground terminal is used to
externally ground the generator.
10 | Westinghouse Outdoor Power Equipment
1
2
3
4
15
14
COMPONENTS
5
6
7
13
12
11. 120-Volt AC,
Receptacles: Each receptacle is capable of
carrying a maximum of 20 amps on a single
receptacle or a combination of both receptacles.
12. 30 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
L5-30R receptacle to 30 amps.
13. 120-Volt AC, 30-Amp NEMA L5-30R Receptacle:
Receptacle can supply a maximum of 30 Amps.
14. 120/240-Volt
Receptacle: Receptacle can supply either 120V or
240V up to 30 amps.
15. 120/240-Volt AC, 50-Amp NEMA 14-50R
Receptacle: Receptacle can supply either 120V
or 240V up to 50 amps.
16. Smart Switch Outlet: Connects the Westinghouse
ST Switch (sold separately) to the control panel
17. CO Sensor indicator lights: The CO Sensor
monitors for the accumulation of poisonous carbon
monoxide gas. If increasing levels of CO gas are
detected, the CO Sensor automatically shuts down
the engine.
18. Battery Indicator: Indicates that power is ON. Light
will remain illuminated while the unit is ON.
8
11
20-Amp
NEMA 5-20R
AC,
30-Amp
NEMA
9
10
GFCI
L14-30R