How to install your oven
As a specialist, you alone are competent to install and connect up De Dietrich
appliances.
Our guarantee therefore applies only and exclusively to appliances which have
been installed and connected up by you in accordance with the provisions of
current regulations.
Failure to meet this requirement would incur the fitter's liability and release the
De Dietrich company from any liability.
Connecting up
Connecting to the mains supply
During the installation of the appliance or when changing the power cable ( H05
RR-F 3x1,5 mm2, H05 RN-F 3x1,5 mm2 or H05 VV-F 3x1,5 mm2) is replaced, loosen
the connection screws completely before attaching the conductors to the
terminals. The earth connector must be attached to the earth terminal of the
appliance.
If you want a permanent connection for your oven, you will require a double pole switch
with gaps of at least 3 mm between contacts.
Otherwise you must ensure the plug of the oven is accessible at all times when the oven is
in its housing.
Operating voltage .....................................................................220-240 V ~ 50 Hz
Total power of oven ..................................................................................2,03 kW
Energy consumption
-Heating to 100°C and maintaining temperature for 1 hour .......................0,90 kWh
Inside dimensions of oven
Width.......................................................................................................38,5 cm
Height......................................................................................................18,2 cm
Depth.......................................................................................................33,5 cm
Effective volume ..................................................................................23,5 litres
22
16:39
Page 22
network voltage
connection
220-240V~ 50Hz
1 Ph + N
400V 3N~ 50Hz
1 Ph + N
min.
diameter of
fuse
cable
3x1,5 mm2
16 A
3x1,5 mm2
16 A