SAFE INSTALLATION
1. The device should be installed by a qualified installer in accordance with all
applicable safety regulations and other regulations.
2. All installations to which the device is connected should comply with the
relevant regulations in force in a given area.
3. The radiator is intended for heating dry rooms. The distances shown in the
illustration below, must be strictly adhered to during installation.
4. The circuit in the electrical installation to which the radiator is connected
must have an appropriate over-current switch and a residual-current device
(R.C.D.) with a sensitivity of 30 mA.
5. In a wet room installation is only possible at the location and as described in
the IEC 60364-7-701 standard.
6. Do not use extension cords or socket adapters to power the radiator.
7. The place where the radiator is connected to the electrical system must not
be behind or directly above the radiator
EN
A - min. 15 cm
B - min. 10 cm
C - min. 50 cm
D - min. 50 cm