User manual
DESCRIPTION OF THE EQUIPMENT (II)
400T-DUO
1-
Reel support Ø 200/300 mm
2-
Accessory box hatch
3-
Cable support
4-
Torch support
5-
HMI (Human Machine Interface)
6-
START/STOP switch
7-
Positive polarity socket
8-
Polarity reversal cable
9-
Negative polarity socket
400T-W
1-
Reel support Ø 200/300 mm
2-
Accessory box hatch
3-
Cable support
4-
Torch support
5-
HMI (Human Machine Interface)
6-
START/STOP switch
7-
Positive polarity socket
8-
Polarity reversal cable
9-
Negative polarity socket
10- Euro connector (torche)
11- Filling cap
HUMAN-MACHINE INTERFACE (HMI)
Please read the Interface User Guide (HMI) which forms part of the complete product literature.
HMI
POWER SWITCH
This machine is fitted with a 32A socket type EN 60309-1 which must only be used on a three-phase 400 V (50-60 Hz) four-wire earthed electrical
installation.
The absorbed effective current (I1eff) is indicated on the device for optimum operating conditions. Check that the power supply and its safeguards
(fuse and/or circuit breaker) are compatible with the electric current being used. In some countries, it may be necessary to change the plug to allow
the use at maximum settings.
• The power source is designed to operate at 400 V +/- 15%. The unit enters protection mode if the supply voltage
is less than 330Vrms or greater than 490Vrms. (An error code will appear on the display screen).
• Starting is done by pressing the START/STOP switch (On), and stopping is done by pressing the same switch (Off). Warning! Never switch off the
power supply while the unit is under load.
CONNECTING TO A POWER SOURCE
This equipment can be operated with electric generators provided that the auxiliary power supply meets the following requirements:
- The voltage must be alternating with an RMS value of 400V +/- 15% and a peak voltage of less than 700V.
- The frequency must be between 50 and 60 Hz.
It is vital to check these conditions as many generators produce high voltage peaks that can damage equipment.
USING EXTENSION LEADS
All extension leads must be of a suitable length and width that is appropriate to the equipment's voltage. Use an extension lead that complies with
national safety regulations.
Input voltage
400 V
SETTING UP THE REEL
a
b
Translation of the original
instructions
Length - Cross-section of the extension cable (Length < 45m)
4mm²
- Remove the nozzle (a) and contact tube (b) from your MIG/MAG torch.
KRONOS 400T DUO / 400T W
10-
Euro connector (torche)
11-
Gas connector
12-
Cover option
13-
Connector for external wire feeder control
14-
Positive polarity socket
15-
Mains cable (5 m)
16-
Bottle holder 4m3 or 10m3
17-
USB hatch
18-
Wire-feed motor
12-
Fuse for cooling unit
13-
Tank level indicator
14-
Liquid coolant outlet (Blue)
15-
Liquid coolant outlet (Red)
16-
Gas connector
17-
Cover option
18-
Mains cable (5 m)
19-
Bottle holder 4m3 or 10m3
20-
USB hatch
21-
Wire-feed motor
22-
Priming hose
25