Télécharger Imprimer la page

Costway FP10269US Mode D'emploi page 6

Publicité

Les langues disponibles

Les langues disponibles

2.2.9 Check electrical devices
Repair and maintenance to electrical components shall include initial
safety checks and component inspection procedures. If a fault exists that
could endanger safety, then no electrical supply shall be connected to the
circuit until it is satisfactorily dealt with. If the fault cannot be corrected
immediately but it is necessary to continue operation, an adequate
temporary solution shall be used. This shall be reported to the owner of
the equipment so all parties are advised.
Initial safety checks shall include:
-those capacitors are discharged: this shall be done in a safe manner to
avoid possibility of sparking;
-that there no live electrical components and wiring are exposed while
charging, recovering or purging the system;
-that there is continuity of earth bonding.
WARNING!
Install the unit in rooms which exceed 4 m²(43 sq.ft).
Do not install the unit in a place where inflammable gas
may leak.
NOTE!
The manufacture may provide other suitable example
or may provide additional information about the
refrigerant odour.
10
3. PRODUCT OVERVIEW
3.1 PRODUCT DIAGRAM
1
2
3
1
Control panel
2
Air outlet with adjustable louver
3
Front panel
4
Air inlet with air filter
5
Recessed handle
6
Air exhaust
7
Drain opening with sealing plug
8
Castor
Note: The appearance is only for reference. Please see the real product for
detailed information.
4
6
7
8
5
11

Publicité