5.4.5.Overload Protection
In the event of a power loss, to protect the compressor, there is a 3-minute delay until the
compressor restarts.
5.5DRAINAGE
Manual drainage:
1)When the machine stops after the water is full, please unplug the power plug.
Notes: Please move the machine carefully, so as not to spill the water in the
water pan at the bottom of the body.
2)Place the water container below the side water outlet behind the body.
3)Unplug the water plug, the water will automatically flow into the water
container.
Notes:
1. Keep the water plug properly.
2. During drainage, the body can be tilted slightly backwards.
3. If the water container cannot hold all the water, before the water container is
full, stuff the water outlet with the water plug as soon as possible to prevent
water from flowing to the floor or the carpet.
4)When the water is discharged,
stuff the water plug.
Notes: 1. Restart the machine after
the water plug and drainage cover
are installed, otherwise condensate
water of the machine will flow to the
floor or the carpet.
20
Continuous drainage
The self-evaporating system uses the collected water to cool the condenser
coils for better efficient performance. There is no need to empty the
drainage tank in cooling operation, except in drying operation and high
humidity conditions. The condensate water evaporates at the condenser
and is evacuated through the exhaust hose.
For continuous operation or unattended operating in drying operation,
please connect the attached drain hose to the unit. Condensate water will
automatically flow into a bucket or drain by gravity.
• Switch off the unit before
operating.
• Remove the plug of the
water outlet opening, and
keep it in safe area.
• Securely and properly
connect the drain hose and
make sure that it is not
kinked and clear of
obstruction.
• Place the outlet of hose
over a drain or bucket and
ensure that water could
freely flow out of the unit.
• Do not submerge the end
of hose into water;
otherwise it can cause "Air
Lock" in the hose.
To avoid water spillage:
• As the negative pressure of condensate drain pan is large, tilt the drain hose
downward toward the floor. It is appropriate that the degree of inclination should
exceed 20 degrees.
• Straighten the hose to avoid a trap existing in the hose.
21