Télécharger Imprimer la page

Costway NP10883 Mode D'emploi page 6

Publicité

Les langues disponibles

Les langues disponibles

Never use a propane cylinder with a damaged body, valve, collar, or
footing.
If you see, smell, or hear the hiss of gas escaping from the propane
cylinder.
1. Turn off the gas supply and get away from the gas cylinder once
2. Do not attempt to correct the problem yourself
3. Contact your gas supplier and/or fire department for help
The LP gas supply tank was constructed and marked in accordance
with the U.S. Department of
Transportation ( D.O. T ) Specifications for LP-GAS Cylinders , or
the Standard for Cylinders,
Transportation of Dangerous Goods and Commission, CAN /
CSA-B339.
LP gas tank must be arranged for vapor withdrawal.
It is essential to keep the outdoor appliance's valve compartment,
burners, and circulating air passages clean. Inspect outdoor
appliances before each use. This outdoor appliance should be
thoroughly cleaned and inspected on a regular basis. Clean and
inspect the hose before each use of the appliance. If there is
evidence of abrasion, wear, cuts, or leaks, the hose must be placed
prior to the appliance being put into operation.
LP Tank used must include a collar to protect the cylinder valves
The LP gas tank must have a listed overfilling prevention device (
OPD ) and QCC or Type I ( CGA791 ) LP gas tank connection.
The LP gas tank should not be dropped or handled roughly.
10
Tanks must be stored outdoors out of the reach of children Do NO
store in buildings, garages, or other enclosed areas.
Never store your LP gas tank where temperatures can reach over
125°F.
Never keep a filled LP gas tank in a hot car's rear trunk. Heat will
cause the gas pressure to increase, which may open the relief valve
and allow gas to escape.
Place dust cap on valve outlet whenever the LP gas tank is not in
use Onlyinstallthe type of dust cap on the LP gas tank valve outlet
that is provided with the gas tank valve. Other types of caps or plugs
may result in leakage of propane.
Do not store a spare LP gas tank under or near this gas appliance
ever fill the tank beyond 80percent full.
LP gas cylinders should only be filled by a certified LP gas dealer
The pressure regulator is set for 11 inches of water column
(pressure).
Any guard or other protective device removed for servicing the
appliance must be replaced prior to operating the appliance.
Installation and repair should be done by a qualified service person.
The appliance should be inspected before use and at least annually
by a qualified service person. More frequent cleaning may be
required as necessary. It is imperative that the control compartment,
burners, and circulating air passageways of the appliance be kept
clean.
The appliance should be inspected before use and at least annually
by a qualified service person.
Do not attempt to disconnect the gas regulator from the tank or any
gas fitting while the outdoor appliance is in use.
Keep the gas appliance away from locations where it can get
excessively wet Do not use the gas appliance if any part has been
underwater.
11