1. Perform a leak test in well-ventilated area outside
2. Make sure any open flames or cigarettes are extinguished.
3. Remove the battery.
4. Ensure the burner control knob is in the"OFF" position
5. Ina bowl, create a soapsolutionusing1 part water and1part liquid
detergent
6. Apply the soapy water solution to all connections.
7. Open the LP tank valve.
8. A gas leak will be detected by expanding bubbles originating from
the point of the leak.
9. If a leak is found at any connection point or if you smell gas, close
the tank valve, disconnect the tank, and do not use the appliance
until repairs can be made.
TIPS: Before Beginning Read and understand the instructions
thoroughly.
Check and make sure that all parts are present.
For future reference, save this instruction sheet.
1. Locate the burner control knob and make sure it is in the "OFF"
position.
2. Connect propane (LP)cylinder. (See above pages).
3. Open LP tank valve slowly.
4. Push in igniter button to create sparks at the electrode and hold.
5. Push and turn burner control knob to the"LOW" position.Continue
to push the control knob for 5 seconds after ignition.
24
LEAK TEST
TO LIGHT
6. If ignition does occurwithin5seconds, turn burner control knob
to"OFF", wait 5minutesfor the gas to clear and repeat the lighting
procedure.If the burner still will not light, refer to the troubleshooting
Section.
7. Once the appliance is lit,flame height can be changed by
adjusting the burner control knob between the"High" and "Low"
8. Always check burner flames periodically to ensure proper
operation. Flames should be mostly yellow with some blue for best
performance. (See diagram)
9. Inspect the burner every time before use, if it is evident that the
burner is damaged or the burner can not light, pls contract the
manufactory to get the appliance to replace it.
10 in
25cm
1 in
2.5cm
Improper lighting procedure will cause
injury or damage
If the burner does not ignite with the burner control valve open,
gas will continue to flow out of the burner and could accidentally
ignite causing injury or property damage.