CONEXIONES ENTRE CONTACTOS IP54/67 Y UNIDAD NC80 /
C
CONNECTIONS BETWEEN IP54/67 AND NC80 UNIT
MAX. 30
UL Certification Requirements
Input terminals
A1 - A2
Auxiliary Outputs (Safety)
Output
terminals
13 - 14
23 - 24
Signaling Outputs (Signal)
Output terminals
41 - 42
≤ 30 m
+
Power Source (Input)
Voltage
24 V DC
Contacts
General use
type
or resistive
3A/240 Vac
NO
Res
Contacts type
NC
+
≤ 500 m, <50Ω/KM
Max. current
100 mA
Pilot duty
-
-
Nom. ratings
3A/30 V DC
AUTOMATIC DOORS FOR LIFTS
NC80
14 24 42
S22 S21 A2(-)
S2
S1
Out
Power
S12 S11 A1(+)
13
23 41
NC80