Power Cord and Strain Relief Replacement
Remove the power cord
1. Remove the screw
2. Use an offset Phillips screwdriver to loosen the set screws
to the top of the power switch.
3. Remove the wires from the power switch.
4. On the outside of the plasma power supply, remove the strain relief retention nut
strain relief. Move the retention nut away from the plasma power supply.
5. Remove the power cord:
CSA: From the outside of the plasma power supply
wires through the strain relief in the rear panel.
CE/CCC: From the inside of the plasma power supply
length of the power cord through the strain relief in the rear panel.
CCC/CE models have ferrite cores
ground wire. To maintain CCC/CE certification, install a CCC/CE power
cord kit.
10
1
that attaches the ground wire to the heatsink.
1
807020
Field Service Bulletin
2
4
6
that attach the 3 power wires
2
, pull the power cord and power
5
, pull the power wires and the full
6
7
on the power wires and the
Powermax65/85, Powermax65/85 SYNC
3
CE/CCC
7
CSA
5
3
from the