3.0 INSTALLATION
THIS APPLIANCE MUST BE INSTALLED IN A SOLID-FUEL BURNING FIREPLACE WITH A WORKING
The appliance and gas logs function as a system. If the appliance is not drafting properly and spilling into the
room (check with a match or a smoke stick), reposition the damper clamp until a positive draft is obtained
by opening the damper. If negative pressure in home prevents having a positive draft, consult an air quality
specialist.
3.1
BATTERY INSTALLATION
A. 4 (1.5 V) AA size batteries are supplied and included in the manual bag.
B. Install the batteries into the battery case.
C. Insert the assembled battery case into the battery support. Ensure that the heat insulation gasket covers
the top and left side of the battery case, as shown below.
3.2
GAS PIPING AND BURNER PLACEMENT
DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE TO ELECTRICITY
This appliance must be isolated from the gas supply piping system by closing the individual manual shut off valve
during any pressure testing of the gas supply piping system at test pressure equal to or less than ½ psi (3.5 kPa)
A.
Centre the burner pan and valve assembly in the fi replace
opening, making sure the appliance is at least 1.5" from the
rear of the fi replace.
B.
Secure the burner to the fi replace fl oor using the 2 screws
provided.
C.
Install the gas line using piping ½" in diameter or greater to
provide the full volume of gas to the appliance. The installation
of the gas line must be done to local and / or National codes.
D.
When rigid pipe is used an ANSI approved manual shut off and
a union must be installed upstream within the appliance cavity.
E.
To ensure the appliance operates reliably install a sediment
trap upstream of the appliance within the structures of the
piping system.
F.
When using propane, a regulator must be used between
the tank and the outside wall of the house to ensure the line
pressure does not exceed 14" w.c. inside the house.
W415-1101 / A / 07.24.12
All manuals and user guides at all-guides.com
FLUE AND CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL.
WARNING
!
LEFT SIDE
WARNING
!
(110 VOLTS).
BOTTOM VIEW
BATTERY SUPPORT
TOP SIDE
INSULLATION
VALVE HOUSING
Regulator
Union
Shut-Off
Appliance
3"
Sediment
Trap
Manual
Shut-Off
Valve
Appliance
Wall
Key