All manuals and user guides at all-guides.com
12
5.0
WIRING DIAGRAM
WARNING
!
DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH.
This appliance comes equipped with a battery pack. Install four AA batteries into the holder and connect to the
wire harness. Connect the battery holder to the wire harness before using the appliance. It must be connected
to the 6 volt battery pack (supplied).
GREEN
ON / OFF
ORANGE
SWITCH
BATTERY
HOLDER
-
+
+
-
ON / OFF
ELECTRONIC
VALVE
VALVE
IPI BOARD
GROUND
EYELET
GROUND
DFC
69.9
W415-1101 / A / 07.24.12