2.2
GENERAL INFORMATION
THIS APPLIANCE MUST NOT BE INSTALLED IN A BEDROOM OR BATHROOM.
Altitude (FT)
Max input (BTU/HR)
Min Inlet Gas Supply Pressure
Max Inlet Gas Supply Pressure
Manifold Pressure (Under Flow
Conditions)
2.3
MINIMUM HEARTH SIZE
HEIGHT
LOG SET
GL22
20"
GL28
20"
GL32
22"
2.4
RATING PLATE
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: ANSI Z21.60-2003/CSA 2.26-2003 (R 2009), DECORATIVE APPLIANCE FOR INSTALLATION IN SOLID-FUEL BURNING
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE
OWNER'S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE. FOR
ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT A QUALIFIED INNSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.
NATURAL GAS MODELS
GL22N
70,000BTU/h
80,000BTU/h
3.5" WATER COLUMN/D'UNE COLONNE D'EAU
4.5" WATER COLUMN/D'UNE COLONNE D'EAU
7.0" WATER COLUMN/D'UNE COLONNE D'EAU
WARNING:
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE
APPLIANCE. FOR ISNTALLATION IN A SOLD-FUEL BURNING FIREPLACE ONLY.
THE FIREPLACE CHIMNEY MUST HAVE A PERMANENT VENT OPENING TO ATMOSPHERE OF NOT
2
"
LESS THAN 56.6
FOR GL22, 64
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
FOR YOUR SAFETY:
VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
FOR MINIMUM CHIMNEY FLUE
SEE INSTRUCTION MANUAL.
POUR LES DIMENSIONS
MINIMALES DE LA CHEMINÉE,
CONSULTEZ LE MANUEL
D'INSTRUCTIONS
THE RATING PLATE IS CHAINED TO THE LEG OF THE VALVE CASE AND SHOULD BE TUCKED
UNDER THE VALVE HOUSING.
This rating plate illustration is for reference only. Refer to the rating plate on the appliance for accurate
information.
All manuals and user guides at all-guides.com
NG
0-4,500
70,000
4.5" Water
Column
7" Water
Column
3.5" Water
Column
WIDTH
DEPTH
A
B
23"
29"
33"
GL28N
GL32N
90,000BTU/h
0-4500FT (0-1370m)
MANIFOLD PRESSURE / PRESSION AU COLLECTEUR
MINIMUM SUPPLY PRESSURE / PRESSION D'ALIMENTATION MINIMALE
MAXIMUM SUPPLY PRESSURE / PRESSION D'ALIMENTATION MAXIMALE
2"
2"
FOR GL28, 71.4
FOR GL32, OR AS DETERMINED BY THE
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
LIANCE
GL22
20"
20"
20"
20"
"
23"
"
GL28
20"
20"
29"
2
22"
22"
GL32
3
33"
WARNING
!
GL22
LP
NG
0-4,500
0-4,500
50,000
80,000
11" Water
4.5" Water
Column
Column
13" Water
7" Water
Column
Column
10" Water
3.5" Water
Column
Column
Do not install the gas log set into a cavity smaller than that
referenced in the table.
C
14"
14"
14"
AVERTISSEMENT:
DES ALTÉRATIONS, UN SERVICE OU UN ENTRETIEN INADÉQUATS PEUVENT CAUSER DES
DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. RÉFÉREZ-VOUS AU
MANUEL D'INSTRUCTIONS FOURNI AVEC CET APPAREIL. POUR DE L'ASSISTANCE OU
C E R T I F I E D
POUR PLUS D'INFORMATION, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE AGENCE
INFORMATION, CONSULTEZ UN INSTA
D'ENTRETIEN OU LE FOURNISSEUR DE GAZ.
N OU LE FOURNISSEUR DE GAZ.
INPUT / ALIMENTATION
ATION
ALTITUDE / ÉLÉVATION
ATION
SION AU COLLECTEU
N D'ALIMENTATION
ESSION D'ALIMENTATI
AVERTISSEME
AVERTISSEMENT:
WITH THE
CONTACT AVEC LES
CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE
FABRICANT.
FABRICANT.
PHERE OF NOT
POUR INSTALLATION DANS UN FOYER Â COMBUSTIBLE SOLIDE SEULEMENT.
POUR INSTALLA
BY THE
LA CHEMINÉE DU FOYER DOIT POSSÉDER UN OUVERTURE D'ÉVACUATION PERMANENTE À L'AIR
LA CHEMINÉE
EXTÉRIEUR
EXTÉRIEUR DE NON MOINS DE 56,6
OU SELO
OU SELON LES INSTRUCTIONS D'INSTALATION DU FABRICANT.
MABLE
POU
POUR VOTRE SÉCURITÉ:
A
AUTRES LIQUIDES ET VAPEURS INFLAMMABLES À PROXIMITÉ DE CET OUT TOUT AUTRE
APPAREIL.
(WSL)
(NAC)
14"
WOLF STEEL LTD.
14"
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA
14"
SERIAL NUMBER/NO. DE SERIE:
GL28
LP
NG
0-4,500
0-4,500
65,000
90,000
11" Water
4.5" Water
Column
Column
13" Water
7" Water
Column
Column
10" Water
3.5" Water
Column
Column
A
B
NSTALLATION IN SOL
NT:
UNE INSTALLATION NON CONFORME, DES AJUSTEMENTS,
UNE INSTALLATION NON C
RVICE OU UN ENTRETIEN INADÉ
DES BLESSURES CORPOREL
RNI AVEC CET APPARE
PROPANE MODELS
G
GL22P
GL28P
50,000BTU/h
50
65,000BTU/h
65,000BTU/h
0-4500FT (0-1370m)
10" WATER COLUMN/D'UNE COLONNE D'EAU
11" WATER COLUMN/D'UNE COLONNE D'EAU
13" WATER COLUMN/D'UNE COLONNE D'EAU
N'AJOUTEZ AUCUN MATÉRIAU À CET APPAREIL QUI ENTRERA EN
2
"
POUR LE GL22, DE 64
2
"
POUR LE GL28 ET 71.4
N'ENTREPOSEZ PAS ET N'UTILISEZ PAS D'ESSENCE OU
(NGZ)
(WUSA)
GSL
5
GL32
LP
0-4,500
65,000
11" Water
Column
13" Water
Column
10" Water
Column
C
GL32P
2
"
POUR LE GL32
W385-0677 A