Télécharger Imprimer la page

PR electronics 5714 Mode D'emploi page 11

Masquer les pouces Voir aussi pour 5714:

Publicité

Les langues disponibles

Les langues disponibles

RULLENDE HJÆLPETEKSTER
Display i Normal tilstand: xxxx
SE.BR --> KABELBRUD
SE.SH --> KORTSLUTTET FOELER
IN.HI
--> INDGANG OVER MAX. VAERDI
IN.LO --> INDGANG UNDER MIN. VAERDI
9.9.9.9 --> DISPLAY OVER MAX. VISNING
-1.9.9.9 --> DISPLAY UNDER MIN. VISNING
HW.ER --> HARDWARE FEJL
EE.ER --> EEPROM MEMORY FEJL
RA.ER --> RAM MEMORY FEJL
CJ.ER --> CJC SENSOR FEJL
NO.CA --> INSTRUMENT IKKE KALIBRERET
Hurtig setpunktsindstilling (Enabled):
REL1
xxxx
--> SETPUNKT RELAE 1 - TRYK OK FOR GEM
REL2
xxxx
--> SETPUNKT RELAE 2 - TRYK OK FOR GEM
Hurtig setpunktsindstilling (Disabled):
REL1
xxxx
--> SETPUNKT RELAE 1 - READ ONLY
REL2
xxxx
--> SETPUNKT RELAE 2 - READ ONLY
Konfigurationsmenuer:
PASS
xxxx
--> ANGIV KORREKT PASSWORD
IN
POTM --> POTENTIOMETER INDGANG
CURR --> STROEM INDGANG
VOLT
--> SPAENDINGS-INDGANG
TEMP --> TEMPERATURFOELER INDGANG
RANG
(volt valgt)
2-10
--> INDGANGSOMRAADE I VOLT
0-10
--> INDGANGSOMRAADE I VOLT
0.2-1
--> INDGANGSOMRAADE I VOLT
0.0-1
--> INDGANGSOMRAADE I VOLT
DEC.P
1111
--> KOMMAPLACERING
111.1
--> KOMMAPLACERING
11.11
--> KOMMAPLACERING
1.111
--> KOMMAPLACERING
DI.LO
xxxx
--> DISPLAYVISNING MIN.
DI.HI
xxxx
--> DISPLAYVISNING MAX.
REL.U
PERC --> INDSTIL SETPUNKT I PROCENT
DISP
--> INDSTIL SETPUNKT I DISPLAYVISNING
REL1
xxxx
--> SETPUNKT RELAE 1
ACT1
INCR
--> AKTIVER FOR STIGENDE SIGNAL
DECR --> AKTIVER FOR FALDENDE SIGNAL
HYS1
xxxx
--> HYSTERESE RELAE 1
ERR1
HOLD --> HOLD RELAE VED FEJL
ACTI
--> AKTIVER RELAE VED FEJL
DEAC --> DEAKTIVER RELAE VED FEJL
NONE --> UDEFINERET STATUS VED FEJL
REL2
xxxx
--> SETPUNKT RELAE 2
ACT2
18
All manuals and user guides at all-guides.com
INCR
--> AKTIVER FOR STIGENDE SIGNAL
DECR --> AKTIVER FOR FALDENDE SIGNAL
HYS2
xxxx
--> HYSTERESE RELAE 2
ERR2
HOLD --> HOLD RELAE VED FEJL
ACTI
--> AKTIVER RELAE VED FEJL
DEAC --> DEAKTIVER RELAE VED FEJL
NONE --> UDEFINERET STATUS VED FEJL
A.OUT
20-4
--> UDGANGSOMRAADE I mA
20-0
--> UDGANGSOMRAADE I mA
4-20
--> UDGANGSOMRAADE I mA
0-20
--> UDGANGSOMRAADE I mA
O.LO
xxxx
--> DISPLAYVAERDI FOR UDGANG MIN.
O.HI
xxxx
--> DISPLAYVAERDI FOR UDGANG MAX.
O.ERR
23mA --> NAMUR NE43 OPSKALERING VED FEJL
3,5mA --> NAMUR NE43 NEDSKALERING VED FEJL
0mA
--> NEDSKALERING VED FEJL
NONE --> UDEFINERET UDGANG VED FEJL
E.PAS
NO
--> AKTIVER PASSWORD BESKYTTELSE
YES
--> AKTIVER PASSWORD BESKYTTELSE
N.PAS
xxxx
--> VAELG NYT PASSWORD
RANG
(strøm valgt)
4-20
--> INDGANGSOMRAADE I mA
0-20
--> INDGANGSOMRAADE I mA
CA.LO
YES
--> KALIBRER POTENTIOMETER LAV
NO
--> KALIBRER POTENTIOMETER LAV
CA.HI
YES
--> KALIBRER POTENTIOMETER HOEJ
NO
--> KALIBRER POTENTIOMETER HOEJ
UNIT
°F
--> VISNING I FAHRENHEIT
°C
--> VISNING I CELSIUS
TYPE
TC.W5 --> TC TYPE W5
TC.W3 --> TC TYPE W3
TC. U --> TC TYPE U
TC. T
--> TC TYPE T
TC. S
--> TC TYPE S
TC. R
--> TC TYPE R
TC. N --> TC TYPE N
TC. L
--> TC TYPE L
TC. K
--> TC TYPE K
TC. J
--> TC TYPE J
TC. E
--> TC TYPE E
TC. B
--> TC TYPE B
PT.4W --> PT-100 4 LEDER
PT.3W --> PT-100 3 LEDER
PT.2W --> PT-100 2 LEDER
DEC.P
(temperatur valgt)
1111
--> KOMMAPLACERING
111.1
--> KOMMAPLACERING
PROGRAMMERING /
BETJENING AF TRYKKNAPPER
Dokumentation til rutediagram
Generelt:
Når du skal konfigurere displayet, bliver du guidet igennem samtlige parametre
og kan vælge netop de indstillinger, der passer til applikationen. Til hver menu
findes en rullende hjælpetekst, som vises i displayet efter 5 sekunder uden
tasteaktivitet.
Konfigurationen udføres ved hjælp af de 3 taster:
forøger talværdien eller vælger næste parameter
formindsker talværdien eller vælger forrige parameter
accepterer valget og går til næste menu
Findes en funktion ikke i modulet, springes alle parametre over for at gøre konfi-
gurationen så enkel som mulig.
Når konfigurationen er gennemført viser displayet - - - -.
Tryk og hold
tasten nede for at gå til forrige menu eller normaltilstand (1.0)
uden at gemme de ændrede tal eller parametre.
Hvis ingen taster har været aktiveret i 2 minutter, returnerer displayet til normal-
tilstand (1.0) uden at gemme de ændrede tal eller parametre.
Uddybende forklaringer:
Hurtig setpunktsindstilling og test af relæer: Med disse menuer kan du fore-
tage hurtig setpunktsændring og relætest.
Ved at trykke på
og
samtidigt aktiveres en relætest, og relæet skifter til-
stand.
Ved kort tryk på
gemmes setpunktsændringen.
Holdes
tasten nede i mere end 0,5 sekund returneres til normaltilstand (1.0)
uden at gemme setpunktsændringen.
Passwordbeskyttelse: Et password kan forhindre adgang til menuer og para-
metre på to niveauer. Passwords mellem 0000 og 4999 giver adgang til hurtig
setpunktsindstilling og relætest. Passwords mellem 5000 og 9999 blokerer
adgang til hurtig setpunktsind stilling og relætest (det aktuelle setpunkt vises
stadig). Default password 2008 giver adgang til alle programmeringsmenuer.
19

Publicité

loading