EN
Problem
Cause
F3
• Temperature sensor-error
F4
• Heating-error
F7
• Motor-error
F9
• Dry temperature sensor-error
FA
• Water level sensor-error
FC1 or
• Abnormal communication-error
FC2
Fd
• Dry heating element-error
FE
• Dry motor-error
UNB
• Unbalanced load-error
• Drying temperature is too high.
H
9.3 Troubleshooting without display code
Problem
Appliance fails to
operate.
Appliance will not be
Appliance is draining
Drainage failure
Cause
• Programme is not yet started.
• Door is not properly closed.
• Machine has not been switched on
• Power failure.
• Child lock is activated
• No water.
• Inlet hose is kinked.
•
• Water pressure is less than 0.03
MPa.
• Door is not properly closed.
• Water supply failure.
• Height of drain hose is below 80
cm.
• Drain hose end could reach into water.
• Drain hose is blocked.
•
• Drain hose end is higher than 100
cm above floor level.
9- Troubleshooting
Solution
• Contact the After sales service.
• Contact the After sales service.
• Contact the After sales service.
• Contact the After sales service.
• Contact the After sales service.
• Contact the After sales service.
• Contact the After sales service.
• Contact the After sales service.
•
C
e h
k c
a
d n
Reduce the load.
• When the temperature exceeds 80 degrees
the drying alarm, when less than 80
degrees the automati lifting of the alarm.
Solution
• Check programme and start it.
• Close the door properly.
• Switch the machine on.
• Check power supply.
• Deactivate child lock.
• Check water tap.
• Check inlet hose.
•
• Check water pressure.
• Close the door properly.
• Ensure the water supply
• Make sure that drain hose is
properly installed.
• Make sure the drain hose is not
in water.
• Unblock drain hose.
•
• Make sure that drain hose is
properly installed.
b
l a
n a
e c
a l
n u
r d
l y
a o
i d
t n
e h
d
u r
. m
25