Miele PDR 944 HW Plan D'installation page 17

Publicité

Les langues disponibles

Les langues disponibles

Possible voltage options
208/240 V   60 Hz   3 Ph
Power source
Total amps
Maximum fuse rating (time-delay fuse)
Minimum current
Exhaust air
Flow rate
Maximum permitted pressure loss
Maximum exhaust air temperature
Exhaust air connector on machine side
As relative humidity inside the exhaust ducting can be as high as 100%, suitable measures must be taken to prevent a backflow of
condensate into the machine.
Supply air
Standard connection: air intake from installation site
Recommended free air intake cross-section into the room:
(equivalent to 3 times the exhaust air cross-section of a machine).
There must be sufficient air intake to the installation site to match the air outlet volume.
Alternative connection: air intake connection directly from outdoors
Connection sleeve on machine side (internal diameter)
Connection pipe provided on site (external diameter)
Removing the protective cover exposes live parts. For safety reasons, a pipe must be installed from the tumble dryer's central fresh air
intake (over a minimum length of 35 7/16" (900 mm)) and secured with 2 screws.
Hot water feed
Rated load
Media temperature operating range
Flow rate operating range
Temperature difference feed/return
Maximum operating pressure
Resistance value at nominal rating (flow rate 1 m³/h)
Threaded union (external thread)
Hot water return
Threaded union (external thread)
Hot water valve
Minimum media temperature
Pressure range
Minimum differential pressure at the control valve (pressureless for circulation system)
Minimum flow factor (k
value)
v
en - Technical data
176°F (80°C)
6" (DN 150)
146 sq. in. (942 cm²)
6 5/16" (161 mm)
6 5/16" (160 mm)
42,677 BTU/hr
158–194°F (70–90°C)
0.3–1.5 m³/h
145 psi (1,000 kPa)
0.145 psi (1 kPa)
212°F (100°C)
0-145 psi (0–10 bar)
208/240 V
60 Hz
3 Ph
10 A
15 A
12.5 A
1,150 m³/h
390 Pa
<15 K
½"
½"
0 psi (bar)
6.0 m³/h
17