BTL5-H1_ _ -M _ _ _ _ -P-S94
Magnetostrictive Linear Position Sensor – Profile Style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The magnetostrictive linear position sensor BTL, together
with a CANopen
master (e.g. PLC) comprises a position
®
measuring system. It is intended to be installed into a
machine or system and used in the industrial sector.
Flawless function in accordance with the specifications in
the technical data is ensured only when using original
Balluff accessories. Use of any other components will void
the warranty.
Opening the BTL or non-approved use are not permitted
and will result in the loss of warranty and liability claims
against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the BTL will not result
in hazards to persons or equipment.
If defects and unresolvable faults occur in the BTL, take it
out of service and secure against unauthorized use.
Downloading further instructions
A complete user's guide and the configuration guide can
be downloaded from the Internet at www.balluff.com or
requested via e-mail from service@balluff.de.
Dimensions and function
The BTL contains the waveguide which is protected by an
aluminum housing. A magnet is moved along the
waveguide. This magnet is connected to the system part
whose position is to be determined. The magnet defines
the position to be measured on the waveguide.
DIP switches S1 for
setting station address
1)
~20
106
~80
Mounting clamps with insulating bushes
and ISO 4762 M5x22 cylinder-head screws,
max. tightening torque 2 Nm
1
english
All manuals and user guides at all-guides.com
Nominal length =
Measuring range
3)
Groove
BTL5-P-3800-2
magnet
DIN912 M5 × 22
~250
Electrical connection
Pin
BUS OUT
1
2
3
4
5
Pin assignment of S94 (view of connector pins of BTL)
BUS OUT
(female)
Configuration
Node ID: adjustable via S1.1...S1.6;
Value 0 = LMT setting
S1.1
S1.2
S1.3
2
0
2
1
LSB
1
2
Baud rate [kBaud]: adjustable via S1.7...S1.9
S1.7
S1.8
S1.9
2
0
2
1
LSB
MSB
1
2
Set Value Baud rate
1
1000
2
800
3
500
4
250
Bus termination: Termination for S1.10 = ON
1)
73
2)
15
~250
~80
1) Unusable area
2) Not included in scope of delivery
3) Groove on the top side of the profile marks the start of measuring range
UL approval
File No.
E227256
BUS IN
CAN_GND
+20...28 V
0 V (GND)
CAN_H
CAN_L
BUS IN
(male)
S1.4
S1.5
S1.6
2
2
2
3
2
4
MSB
4
8
16
2
2
4
Set Value
Baud rate
5
125
6
100
7
50
0
LMT setting
50
68
2
5
32

Publicité