Télécharger Imprimer la page

PR electronics 5335 Mode D'emploi page 13

Masquer les pouces Voir aussi pour 5335:

Publicité

Les langues disponibles

Les langues disponibles

Cable resistance per wire (max.)................. 5 Ω
Sensor current............................................. Nom. 0.2 mA
Effect of sensor cable resistance
(3- / 4-wire).................................................. < 0.002 Ω/Ω
Sensor error detection ................................ Yes
Short circuit detection................................. If 0% > 30 Ω
TC input:
Min.
Max.
Type
temperature
temperature
B
+400°C
+1820°C
E
-100°C
+1000°C
J
-100°C
+1200°C
K
-180°C
+1372°C
L
-100°C
+900°C
N
-180°C
+1300°C
R
-50°C
+1760°C
S
-50°C
+1760°C
T
-200°C
+400°C
U
-200°C
+600°C
W3
0°C
+2300°C
W5
0°C
+2300°C
Cold junction compensation ....................... < ±1.0°C
External CJC with Ni100 or Pt100 .............. -40 ≤ T amb. ≤ 135°C
Sensor error detection ................................ Yes
Sensor error current:
When detecting.................................... Nom. 33 µA
Else ...................................................... 0 µA
Short circuit detection................................. If 0% > 5 mV
Voltage input:
Measurement range .................................... -800...+800 mV
Min. span..................................................... 2.5 mV
Input resistance........................................... 10 MΩ
Current output:
Signal range ................................................ 4...20 mA
Min. signal range......................................... 16 mA
Updating time.............................................. 440 ms
Fixed output signal...................................... Between 4 and 20 mA
Output signal at EEprom error .................... ≤ 3.5 mA
Load resistance ........................................... ≤ (V
Load stability ............................................... < ±0.01% of span / 100 Ω
22
All manuals and user guides at all-guides.com
Min.
span
Norm
100°C
IEC584
50°C
IEC584
50°C
IEC584
50°C
IEC584
50°C
DIN 43710
50°C
IEC584
100°C
IEC584
100°C
IEC584
50°C
IEC584
50°C
DIN 43710
100°C
ASTM E988-90
100°C
ASTM E988-90
(660 ms for diff.)
- 8) / 0.023 [Ω ]
supply
Sensor error detection:
Programmable............................................. 3.5...23 mA
NAMUR NE43 Upscale ............................... 23 mA
NAMUR NE43 Downscale........................... 3.5 mA
Ex data:
Signal output / supply, terminal 1 to 2:
U i ................................................................. : 30 VDC
I i .................................................................. : 120 mADC
P i ................................................................. : 0.84 W
L i ................................................................. : 10 µH
C i ................................................................. : 1.0 nF
Sensor input, terminal 3, 4, 5 and 6:
U o ............................................................... : 9.6 VDC
I o ................................................................. : 28 mA
P o ................................................................ : 67 mW
L o ................................................................ : 35 mH
C o ................................................................ : 3.5 µF
EEx approval CENELEC:
DEMKO 99 .................................................. ATEX 126965
ATEX .......................................................... 0539
Max. amb. temperature for T1...T4 ............. 85°C
Max. amb. temperature for T5 and T6 ....... 60°C
Applicable in zone ....................................... 0, 1 or 2
FM ............................................................... IS, CL. I, DIV. 1, GP. A-D
Entity, FM Control Drawing No. ................. 5300Q502
CSA ............................................................. Class I, Zone 0/1, Group IIC
Installation Drawing No. .............................. 533XQC03
Observed authority requirements:
EMC 89/336/EEC, Emission ....................... EN 50 081-1, EN 50 081-2
Immunity ....................... EN 50 082-2, EN 50 082-1
Emission and immunity ....................... EN 61 326
ATEX 94/9/EC.............................................. EN 50 014 and EN 50 020
Factory Mutual, ASCN ................................ 3600, 3810, 3611, 3610
CSA, CAN / CSA ......................................... E79-15, E79-11
Of span = Of the presently selected range
II 1 G
EEx ia IIC T1...T6
Standard:
23