Figure 3-5. Exhaust Hazard
3.3.1— Grounding Generator If Used as Portable
See Figure 3-6. An equipment ground connects the gen-
erator frame components to ground terminals on the AC
output receptacles. This allows the generator to be used
as a portable without grounding the frame as specified in
NEC 250.34.
3.3.1.1—Special Requirements
There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes,
or ordinances that apply to the intended use of the gener-
ator.
Consult a qualified electrician, electrical inspector, or the
local agency having jurisdiction:
In some areas, generators are required to be regis-
tered with local utility companies.
If the generator is used at a construction site, there
may be additional regulations which must be
observed.
3.3.2— Connecting to Building Electrical System
Use a manual transfer switch when connecting directly to
a building electrical system. Installation and connections
must be performed by a qualified electrician and in strict
compliance with all national and local electrical codes
and laws.
Owner's Manual for Portable Generator
Figure 3-6. Equipment Ground
3.3.3— Connecting Electrical Loads
Verify that the generator is the correct voltage
and frequency for the attached loads.
Let engine stabilize and warm up for a few minutes
1.
after starting.
Plug in and turn on the desired electrical loads.
2.
Add up the rated watts (or amps) of all loads to be
3.
connected at one time. The total should not
exceed:
a. The rated wattage/amperage capacity of the
generator or
b. Circuit breaker rating of the receptacle supplying
the power.
NOTE: See Subsection 3.4 — Do Not Overload Gen-
erator.
Operation
11