The Oventrop Quality Management
System is certified to DIN EN ISO 9001.
Tender specification:
Oventrop radiator lockshield valve "Combi 4"/"Combi C"
with proportional fine presetting with memory position for use in
hot water central heating systems and for chilled water circuits.
For presetting, isolating, filling and draining of the radiator.
Made of bronze/brass, nickel plated ("Combi C" - chrome
plated), valve disc with EPDM O-ring seal.
Protection cap with additional sealing function.
Connection for service tool.
Suitable for threaded pipes or compression fittings.
Lengths according to DIN 3842.
Working temperature t
:
2 °C up to 120 °C
s
(for short periods up to 130°C)
Max. working pressure p
:
10 bar
s
Oventrop radiator lockshield valve "Combi 3"
with proportional fine presetting for use in hot water central
heating systems and for chilled water circuits.
For presetting, isolating, filling and draining of the radiator.
Made of bronze/brass, nickel plated, valve disc with EPDM
O-ring seal.
Protection cap with additional sealing function.
Connection for service tool.
Suitable for threaded pipes, compression fittings and press
connection.
Lengths according to DIN 3842.
Working temperature t
:
2 °C up to 120 °C
s
(for short periods up to 130°C)
Max. working pressure p
:
10 bar
s
Oventrop radiator lockshield valve "Combi 2"
with proportional fine presetting for use in hot water central
heating systems and for chilled water circuits.
For presetting and isolating of the radiator.
Made of brass, nickel plated, valve disc with EPDM O-ring seal.
Protection cap with additional sealing function.
Suitable for threaded or solder pipes or compression fittings.
Lengths according to DIN 3842.
Working temperature t
:
2 °C up to 120 °C
s
(for short periods up to 130°C)
Max. working pressure p
:
10 bar
s
Function:
The Oventrop radiator lockshield valves "Combi 4, 3, 2 and C"
are installed in the return pipe of the radiator. When installing
"Combi 4, 3 and C", please ensure that the draining facility for
draining the radiator is accessible. This will allow the removal of
radiators without the necessity to drain the system.
To carry out the hydronic balancing with the heating system, a
presetting can be made to alter the flow resistance.
Draining and filling of the radiator ("Combi 4, 3 and C" only) is
carried out using the service tool.
Application:
- Hot water central heating systems
- Chilled water circuits
"Combi 4 and C" radiator lockshield valve with the following
functions:
- Presetting with memory position
- Isolating
- Filling
- Draining
"Combi 3" radiator lockshield valve with the following functions:
- Presetting
- Isolating
- Filling
- Draining
"Combi 2" radiator lockshield valve with the following functions:
- Presetting
- Isolating
Note:
When using compression fittings, the Oventrop radiator lock-
shield valves can also be used in installations with Oventrop
composition pipe "Copipe" (14 and 16 mm) as well as copper
pipe (10-22 mm). The models with G
used for precision steel, stainless steel and plastic pipes as well
as the Oventrop composition pipe "Copipe".
Press connection:
For the direct connection of copper pipes according to DIN EN
1057/DVGW GW 392, stainless steel pipes according to DIN EN
10088/DVGW GW 541 and thin-walled C-steel pipe(material no.
E 195/1.0034) according to DIN EN 10305-3. Pressing must be
carried out to tighten the connection. Only use press jaws with
the original contours SANHA (SA), Geberit- Mapress (MM) or
Viega (Profipress) in corresponding size.
Processing must be carried out according to the installation
instructions.
All manuals and user guides at all-guides.com
EN
3
male thread can also be
4
Valves, controls + systems
Radiator lockshield valves "Combi 4",
"Combi 3", "Combi 2" and "Combi C"
Radiator lockshield valve "Combi 4"
Cut illustrations:
"Combi 4 and C" angle pattern with female thread according
to EN 10226-1
"Combi 3" angle pattern with female thread according
to EN 10226-1
"Combi 2" angle pattern with female thread according
to EN 10226-1