UL-Data
The safety functions were not evaluated by UL. Listing is accom-
plished according to requirements of Standard UL 508, "general use
applications"
Nominal voltage U
:
N
Ambient temperature:
Switching capacity:
Ambient temperature 50°C:
Semiconductor outputs:
Wire connection:
Technical data that is not stated in the UL-Data, can be found
in the technical data section.
nfo
CCC-Data
Thermal current I
:
th
Switching capacity
to AC 15:
to DC 13:
Technical data that is not stated in the CCC-Data, can be found
in the technical data section.
nfo
All manuals and user guides at all-guides.com
DC 24 V
0 ... +50°C
Pilot duty B300
5A 250Vac G.P.
5A 24Vdc
24Vdc, 100 mA
60°C / 75°C copper conductors only
AWG 20 - 12 Sol Torque 0.8 Nm
AWG 20 - 14 Str Torque 0.8 Nm
4 A
3 A / AC 230 V
IEC/EN 60947-5-1
1 A / DC 24 V
IEC/EN 60947-5-1
Fault indication by flashing code
The failure codes are displayed by a flashing sequence of the upper yellow
LEDs run 1, run 2. Flashing frequence: env. 0,5 s on, 0,05 s off, end od the
sequence: env. 2 s off. It is possible that the two processors show different
failure codes.
If a failure is displayed, the relays K1 and K2 are switched off.
These failures are serious and do not allow further operation of the module.
They are indicated only by the LEDs run 1 and / or run 2 of the module. The
semiconductor outputs 48 and 58 are both switched off. The module can
only be reset by switching the power supply off and on again.
N
*
Description
o
)
Internal module failure
0
(LEDs are continuously off)
5
Adjustment failure
Undervoltage detection
6
ou
Overvoltage detection
7
Input failure
8
Failure on relays K1 or K2
9
10
Internal module failure
11
12
13
Internal module failure
14
*) No.: Number of flash pulses in a series
38
Mesures et conseils
If both LEDs stay off, the mo-
dule is defective and has to be
repaired.
1) The settings of the 2
channels are not identically.
2) The selected setting is not
permitted.
1) Left LED is flashing:
The supply voltage dropped
below the permitted value
(< approx.0.85 U
)
N
2) Right LED is flashing:
The supply voltage went over
the permitted value
(> approx.1.15 U
+ 5 %
N
residual ripple)
1) A short circuit has been
detected on the inputs of
the unit.
2) The 2 signals of a 2-channel
sensor (E-stop button, light
curtain) are not identical.
(Short circuit, broken wire,
other defects).
Check circuit and current.
Module has to be repaired.
Please try to evaluate the
circumstances that lead to this10
fault and check with the supplier
or manufacturer.
The module has to be repaired
BH 5910 / 200217 / 190A