Télécharger Imprimer la page

schmalz Vacuostat VSi HD Notice D'utilisation page 34

Publicité

IO-Link Data Dictionary
21.10.01.00176/00
IO-Link Implementation
Vendor ID
Device ID
SIO-Mode
IO-Link Revision
IO-Link Profile
IO-Link Bitrate
Minimum Cycle Time
Process Data Input
Process Data Output
Process Data
Process Data Input
Name
PD In Byte 0
Vacuum in mbar, MSB
Vacuum in mbar, LSB
PD In Byte 1
Switching Point 2
Switching Point 1
ISDU Parameters
ISDU Index
Subindex
dec
hex
dec
Identification
Device Management
16
0x0010
0
Vendor Name
17
0x0011
0
Vendor Text
18
0x0012
0
Product Name
19
0x0013
0
Product ID
20
0x0014
0
Product Text
21
0x0015
0
Serial Number
22
0x0016
0
Hardware Revision
23
0x0017
0
Firmware Revision
240
0x00F0
0
Unique ID
241
0x00F1
0
Device Features
250
0x00FA
0
Article Number
251
0x00FB
0
Article Revision
Production Date
252
0x00FC
0
Detailed Product Text
254
0x00FE
0
Device Localization
24
0x0018
0
Application Specific Tag
25
0x0019
0
Function Tag
26
0x001A
0
Location Tag
242
0x00F2
0
Equipment Identification
246
0x00F6
0
Geolocation
247
0x00F7
0
IODD Web Link
249
0x00F9
0
Storage Location
253
0x00FD
0
Installation Date
Parameter
Device Settings
Commands
System Command
2
0x0002
0
58
0x003A
0
Teach-In Channel
59
0x003B
0
Teach-In Status
Initial Settings
73
0x0049
0
Signal Type
Process Settings
Switch Point 1
60
0x003C
1
Switch Point 1 - Upper Threshold
60
0x003C
2
Switch Point 1 - Lower Threshold
61
0x003D
1
Switch Point 1 - Logic
61
0x003D
2
Switch Point 1 - Mode
61
0x003D
3
Switch Point 1 - Window Hysteresis
75
0x004B
1
Switch Point 1 - Switch-on delay
75
0x004B
2
Switch Point 1 - Switch-off delay
Switch Point 2
62
0x003E
1
Switch Point 2 - Upper Threshold
Switch Point 2 - Lower Threshold
62
0x003E
2
63
0x003F
1
Switch Point 2 - Logic
63
0x003F
2
Switch Point 2 - Mode
63
0x003F
3
Switch Point 2 - Window Hysteresis
80
0x0050
1
Switch Point 2 - Switch-on delay
80
0x0050
2
Switch Point 2 - Switch-off delay
Condition Monitoring [CM]
Permissible Leakage Rate
108
0x006C
0
Observation
Monitoring
Process Data
40
0x0028
0
Process Data In Copy
64
0x0040
1
Sensor Value
J. Schmalz GmbH
Bits
Data Type
7...0
VSi V: 14-bit unsigned integer
7...2
1
Boolean
0
Boolean
Parameter
Size
Value Range
1...32 bytes
1...32 bytes
1...32 bytes
1...32 bytes
1...32 bytes
9 bytes
2 bytes
4 bytes
20 bytes
11 bytes
14 bytes
2 bytes
3 bytes
1...64 bytes
1...32 bytes
1...32 bytes
1...32 bytes
1...64 bytes
1...64 bytes
1...64 bytes
1...32 bytes
1...16 bytes
5, 65, 130, 165,
1 byte
66, 167, 168, 169
1 byte
1, 2
1 byte
1 byte
0 - 1
2 bytes
999 > SP1 > RP1
2 bytes
0 < RP1 < SP1
1 byte
0 - 1
1 byte
2, 3, 128, 129
2 bytes
2 bytes
0 - 999
2 bytes
0 - 999
2 bytes
999 > SP2 > RP2
2 bytes
0 < RP2 < SP2
1 byte
0 - 1
1 byte
2, 3, 128, 129
2 bytes
2 bytes
0 - 999
2 bytes
0 - 999
2 bytes
0 - 999
2 bytes
2 bytes
234 (0x00EA)
100616 (0x018908)
Yes
1.0
Smart Sensor Profile with 2 Binary Data Channels, 1 Process Data Variable, Teach-In and Diagnosis
38.4 kBit/sec (COM2)
2.3 ms
2 bytes
None
Access
Special Values
ro
VSi V: 10000 = Overflow, 16383 = Underflow (pressure)
ro
ro
Access
Default Value
ro
J. Schmalz GmbH
ro
Innovative Vacuum Solutions
ro
VSi / VSi-D
ro
VSi / VSi-D
ro
VSi V M12-4
ro
000000001
ro
00
ro
1.11
ro
ro
ro
10.06.02.*
ro
00
ro
ro
VSi V M12-4
rw
***
rw
***
rw
***
rw
***
rw
***
rw
***
rw
***
rw
***
wo
rw
1
ro
rw
0
rw
750
rw
600
rw
0
rw
3
rw
20
rw
0
rw
0
rw
550
rw
500
rw
0
rw
3
rw
20
rw
0
rw
0
rw
200
ro
ro
1 of 2
VSi HD series
J. Schmalz GmbH
Johannes-Schmalz-Str. 1, D 72293 Glatten
Tel.: +49(0)7443/2403-0
www.schmalz.com
info@schmalz.de
Remark
Most significant 8 bits of sensor measurement value (mbar)
Least significant 6 bits of sensor measurement value (mbar)
Logic state of switch point 2
Logic state of switch point 1
Remark
Manufacturer designation
Vendor text
General product name
Product variant name
Order-code
Serial number
Hardware revison
Firmware revision
Unique device identification number
Type code of device features (see IODD)
Order-number
Article revision
Date code of production (month, year)
Detailed type description of the device
User string to store location or tooling information
User string to store function
User string to store location
User string to store identification name from schematic
User string to store geolocation from handheld device
User string to store web link to IODD file
User string to store storage location
User string to store date of installation
0x05 (dec 5): Force upload of parameter data into the master
0x41 (dec 65): Execute single-value teach for currently selected SPx
0x81 (dec 129): Application Reset
0x83 (dec 131): Back-To-Box
0xA5 (dec 165): Calibrate sensor
0xA7 (dec 167): Reset erasable counters ct1 and ct2
0xA8 (dec 168): Reset min/max values of supply voltage
0xA9 (dec 169): Reset min/max values of sensor
Select switch point 1 or 2 for teaching
Result of last teach-in command:
0x00 = Channel changed
0x07 = Teach-in failed
0x11 = Teach-in successful
0 = PNP
1 = NPN
Unit mbar
Unit mbar
0 = Non-inverted / Normally open
1 = Inverted / normally closed
2 = Window mode
3 = Two-Point mode
128 = Condition monitoring Mode
129 = Diagnostic mode
Unit mbar
Unit ms
Unit ms
Unit mbar
Unit mbar
0 = NO
1 = NC
2 = Window Mode
3 = Two-Point Mode
128 = Condition Monitoring
129 = Diagnostic Mode
Unit mbar
Unit ms
Unit ms
Unit mbar/sec
Copy of currently active process data input
Actual sensor value
21.04.2022
VSi Data Dictionary

Publicité

loading