ELECTRICAL CONNECTIONS
EN
Disconnect power before servicing the product.
Failure to do so could result in death or
electrical shock .
General information
The models may be powered at 240V or
208V.
This cooktop does not require a neutral connection. If
the cooktop is to be completely enclosed in a cabinet,
feed the cooktop cable through the opening in the
cabinet. Make the electrical connection following the
appropriate steps for your installation.
Your cooktop must be connected to the proper
electrical voltage and frequency as specified in the
table on the right.
Figure 12. Location of serial tag
Improper connection of aluminum house
wiring can result in a re or shock hazard.
Use only connectors designed and certi ed
for connecting to aluminum wire, and
installed by a quali ed electrician.
8
©2018 Hestan Commercial Corporation
All manuals and user guides at all-guides.com
This touch control works using optical light sensing
technology. When first connecting electrically or
after a power failure, any direct strong light over the
sensor area may affect the touch control functionality.
When powering on the unit make sure that no strong
light is shining directly over the touch control zone,
it can compromise the start-up sensor calibration
resulting in an unresponsive touch control.
The flexible conduit (supplied) 3 feet long (100 cm)
located at the right rear of the cooktop bottom box
should be connected directly to junction box. Do not
cut the conduit. A U.L - or CSA - listed conduit
connector must be provided at each end of the power
supply cable (at the cooktop and at the junction box.)
A time delay fuse or circuit breaker is recommended.
Do not ground to a gas pipe. Do not have a fuse in the
grounding or neutral circuit.
Fuse both supply (phase) lines.
Power Supply
240 V 60 Hz
Model
7
1 .
k
W
2
3
" 0
KEC 30**
KEC 36**
9
9 .
k
W
4
1
3
" 6
National Fire Protection Association
Batter/march Park Quincy, Massachusetts 02269
A three-wire, single phase, 240 Volt 60 cycle electrical
system (properly circuit protected to meet Local
Codes of NFPA No.70) must be provided. Unit must
be properly grounded in accordance with local wiring
code. The chart below recommends the minimum
circuit protector and wire size if the appliance is the
only unit on the circuit. If smaller sizes of wire are
used, the unit efficiency will be reduced and a fire
hazard may be created. It is advisable that the
electrical wiring and hookup be accomplished by a
competent electrician.
208 V 60 Hz
9
6 .
A
5
3 .
3
k
W
2
5
6 .
A
3 .
A
7
4 .
3
k
W
3
5
8 .
A