3. If programmed as an input, you can
connect a device - such as a door
contact - to the 'Z/P' terminal of the
LCD5511. This eliminates the need to
run wires back to the control panel for
the device. To connect the zone, run
one wire from the device to the 'Z/P'
terminal and the other wire from the
device to the B (black) terminal. For
powered devices, run the red wire to
the R (positive) terminal and the black
wire to the B (negative) terminal. When
using end of line supervision, connect
the zone according to one of the con-
figurations outlined in your system's
Installation Manual.
4. If the 'Z/P' terminal is programmed as
an output, the output follows the PGM
programmed in Section [000][8]. A
small relay, buzzer or other DC operat-
ed device may be connected between
the positive supply voltage and the 'Z/
P' terminal (maximum load is 50mA).
Applying Power
Once all wiring is complete, apply power
to the control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel
power specifications, see the control
panel Installation Manual.
NOTE: Do not connect the power until all wir-
ing is complete.
Enrolling the Keypad
Once all wiring is complete, you will need
to enter a 2-digit number that tells the
system the partition and slot assignment
of the keypad.
If your system has partitions, you will
need to also assign the keypad to a par-
tition (1st digit).
The slot assignment (2nd digit) tells the
panel which keypad slots are occupied.
The panel can then generate a fault when
a keypad supervisory signal is not
present. There are eight available slots
for keypads. LCD5511 keypads are al-
ways assigned to slot 1 by default. You
will need to assign each keypad to its
own slot (1 to 8).
Enter the following at each keypad in-
stalled on the system:
Enter Installer Programming by press-
✱
ing [
][8][Installer's Code]
Press [000] for Keypad Programming
Press [0] for Partition and Slot Assign-
ment
Enter a two digit number to specify the
partition and slot assignment.
NOTE: If your system does not have partitions,
enter [1] for the first digit.
1st digit Enter 0 for Global Keypad
Enter 1 for Partition 1 Keypad
Enter 2 for Partition 2 Keypad
Enter 3 for Partition 3 Keypad
Enter 4 for Partition 4 Keypad
Enter 5 for Partition 5 Keypad
Enter 6 for Partition 6 Keypad
Enter 7 for Partition 7 Keypad
Enter 8 for Partition 8 Keypad
2nd digit Enter 1 to 8 for Slot Assignment
5. Press the [#] key twice to exit pro-
gramming.
6. After assigning all keypads, perform a
supervisory
✱
[
][8][Installer's Code][902]. The pan-
el will now supervise all assigned key-
pads and enrolled modules on the
system.
Programming the Keypad
There are several programming options
available for the LCD5511 keypad. These
are described below. Record all your
programming choices in the program-
ming worksheets included in this manual.
Programming the LCD5511 is similar to
programming the rest of the system.
When you are in the LCD5511 program-
ming sections, the keypad will display
which options are turned on along the top
of the display. To turn an option on or off,
press the number corresponding to the
option on the number pad. The numbers
of the options that are currently turned
ON will be displayed.
2
reset
by
entering